Biocompatibility of intraocular lenses
- PMID: 12861109
- DOI: 10.1097/01.ICL.0000072833.79456.2D
Biocompatibility of intraocular lenses
Abstract
Purpose: The choice of intraocular lens (IOL) implanted by cataract surgeons has significant implications for the effectiveness of the operation and the subsequent need for capsulotomy.
Methods: Comparison of pertinent peer-reviewed literature published from 1996 through 2001 obtained from a MEDLINE literature search on biocompatibility indicators and IOLs. This review pertains to routine, uncomplicated cataract surgery, and thus, the findings may not be relative to complicated surgeries. Currently available IOLs were not included in this review if no published data on the IOL were available. However, representative lenses from all the major biomaterial classes were included.
Results: Overall results of a comparison of published accounts of posterior capsular opacification, Nd:YAG capsulotomies, anterior capsular opacification, aqueous flare, cellular reaction, capsular adhesion, and capsular stability show a polyacrylic elastomer to be the most highly biointegrated IOLs by the human eye.
Conclusions: Most evidence published in peer-reviewed journals suggests a clear IOL choice for cataract surgeons. In the field of implantable medical devices, one device in a category does not usually provide consistently superior performance of its intended function. The ability of the biomaterial to maintain a clear optical axis not only by suppressing the proliferation of lens epithelial cells, and thus inhibiting posterior capsular opacification formation and obviating the need for an Nd:YAG capsulotomy, but also by adhering to and stabilizing the capsular bag is, to date, unmatched by any other IOL available.
Similar articles
-
Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II: Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification.Ophthalmology. 1999 May;106(5):891-900. doi: 10.1016/S0161-6420(99)00506-0. Ophthalmology. 1999. PMID: 10328386
-
Comparison of Nd : YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, or acrylic intra-ocular lenses in four European countries.Ophthalmic Epidemiol. 2004 Oct;11(4):319-29. doi: 10.1080/09286580490515116. Ophthalmic Epidemiol. 2004. PMID: 15512993
-
Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with a round-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgery.J Cataract Refract Surg. 2009 Mar;35(3):459-65. doi: 10.1016/j.jcrs.2008.11.044. J Cataract Refract Surg. 2009. PMID: 19251138
-
Relationship between posterior capsule opacification and intraocular lens biocompatibility.Prog Retin Eye Res. 2004 May;23(3):283-305. doi: 10.1016/j.preteyeres.2004.02.004. Prog Retin Eye Res. 2004. PMID: 15177204 Review.
-
Prevention of postoperative capsular bag opacification using intraocular lenses and endocapsular devices maintaining an open or expanded capsular bag.J Cataract Refract Surg. 2016 Mar;42(3):469-84. doi: 10.1016/j.jcrs.2016.02.010. J Cataract Refract Surg. 2016. PMID: 27063529 Review.
Cited by
-
Biomaterial Influence on Intraocular Lens Performance: An Overview.J Ophthalmol. 2018 Mar 15;2018:2687385. doi: 10.1155/2018/2687385. eCollection 2018. J Ophthalmol. 2018. PMID: 29736282 Free PMC article. Review.
-
Biocompatibility of Intraocular Lenses.Turk J Ophthalmol. 2017 Aug;47(4):221-225. doi: 10.4274/tjo.10437. Epub 2017 Aug 15. Turk J Ophthalmol. 2017. PMID: 28845327 Free PMC article. Review.
-
Outcome of phacoemulsification in patients with uveitis.Br J Ophthalmol. 2007 Jul;91(7):916-21. doi: 10.1136/bjo.2007.114801. Epub 2007 Jan 17. Br J Ophthalmol. 2007. PMID: 17229800 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources