Thrombolysis for prosthetic valve malfunction: case report and review
- PMID: 12866777
Thrombolysis for prosthetic valve malfunction: case report and review
Abstract
A 40 year old female with severe mitral valve stenosis, underwent mitral valve replacement by single disc valve 4 years ago. She presented at this admission with a new onset of congestive heart failure. The prothrombin time was inadequate with international normalized ratio (INR) 1.43. Transthoracic echocardiography revealed high pressure gradient across the mitral valve. Fluoroscopy demonstrated restrictive opening of single disc motion. Intravenous thrombolysis was given for presumptive diagnosis of prosthetic valve thrombosis. The patient gradually improved and did not have to undergo surgical correction.
Similar articles
-
[Severe mixed prosthetic double-discs mitral valve dysfunction due to thrombosis - a case report].Kardiol Pol. 2009 Jan;67(1):58-60; discussion 61. Kardiol Pol. 2009. PMID: 19253192 Polish.
-
First-degree atrioventricular block: a cause of false malfunction of a mitral disc-valve prosthesis. Case report.J Thorac Cardiovasc Surg. 1975 May;69(5):776-80. J Thorac Cardiovasc Surg. 1975. PMID: 1127976
-
[Systemic thrombolysis in acute obstruction of an artificial valve].Orv Hetil. 1991 Oct 20;132(42):2323-5. Orv Hetil. 1991. PMID: 1945369 Hungarian.
-
[Thrombosis of a prosthetic mitral valve in the anticardiolipin syndrome].Dtsch Med Wochenschr. 1995 Jun 2;120(22):795-8. doi: 10.1055/s-2008-1055410. Dtsch Med Wochenschr. 1995. PMID: 7781511 Review. German.
-
[The best of valvular heart disease in 2006].Arch Mal Coeur Vaiss. 2007 Jan;100 Spec No 1:19-28. Arch Mal Coeur Vaiss. 2007. PMID: 17405561 Review. French.