Cerebral aneurysm regrowth and coil unraveling after incomplete Guglielmi detachable coil embolization: serial angiographical and histological findings
- PMID: 12870547
- DOI: 10.2176/nmc.43.293
Cerebral aneurysm regrowth and coil unraveling after incomplete Guglielmi detachable coil embolization: serial angiographical and histological findings
Abstract
A 69-year-old woman suffered subarachnoid hemorrhage due to rupture of an aneurysm at the tip of the basilar artery. The aneurysm was treated by endovascular treatment using Guglielmi detachable coils but the aneurysm dome could not be completely packed. Serial angiography at 10 and 18 months after embolization showed progressive regrowth of the aneurysm with loosening and unraveling of the packed coils. The patient died accidentally after head injury and autopsy was performed. Examination of the aneurysm showed further regrowth and "relative coil compaction" of the coil mass. Histological examination of the resected aneurysm showed no endothelialized membrane in the orifice and only minimal organized thrombus in the body of the aneurysm.
Similar articles
-
Retrieval of a Guglielmi detachable coil after unraveling and fracture: case report and experimental results.Neurosurgery. 1994 Nov;35(5):994-8; discussion 999. doi: 10.1227/00006123-199411000-00038. Neurosurgery. 1994. PMID: 7838356
-
Delayed exacerbation of third nerve palsy due to aneurysmal regrowth after endovascular coil embolization.J Neuroophthalmol. 2004 Mar;24(1):3-10. doi: 10.1097/00041327-200403000-00002. J Neuroophthalmol. 2004. PMID: 15206431 Review.
-
Ballonn-assisted Guglielmi detachable coiling of wide-necked aneurysma: Part II--clinical results.Neurosurgery. 1999 Sep;45(3):531-7; discussion 537-8. doi: 10.1097/00006123-199909000-00024. Neurosurgery. 1999. PMID: 10493375
-
Selective occlusion of basilar artery aneurysms using controlled detachable coils: report of 35 cases.Neurosurgery. 1996 May;38(5):948-53; discussion 953-4. doi: 10.1097/00006123-199605000-00019. Neurosurgery. 1996. PMID: 8727820
-
Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery. Case report and review of the literature.J Neurosurg. 1997 Dec;87(6):944-9. doi: 10.3171/jns.1997.87.6.0944. J Neurosurg. 1997. PMID: 9384409 Review.
Cited by
-
How do coil configuration and packing density influence intra-aneurysmal hemodynamics?AJNR Am J Neuroradiol. 2011 Nov-Dec;32(10):1935-41. doi: 10.3174/ajnr.A2635. Epub 2011 Sep 1. AJNR Am J Neuroradiol. 2011. PMID: 21885712 Free PMC article.
-
Computerized assessment of angiographic occlusion rate and coil density in embolized human cerebral aneurysms.AJNR Am J Neuroradiol. 2009 May;30(5):1046-53. doi: 10.3174/ajnr.A1463. Epub 2009 Mar 19. AJNR Am J Neuroradiol. 2009. PMID: 19299484 Free PMC article. Clinical Trial.
-
The Medina Embolic Device: Karolinska experience.Interv Neuroradiol. 2018 Feb;24(1):4-13. doi: 10.1177/1591019917733125. Epub 2017 Sep 28. Interv Neuroradiol. 2018. PMID: 28956513 Free PMC article.
-
Histopathologic evaluation of aneurysms treated with Guglielmi detachable coils or matrix detachable microcoils.AJNR Am J Neuroradiol. 2006 Feb;27(2):283-8. AJNR Am J Neuroradiol. 2006. PMID: 16484393 Free PMC article.