Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts
Abstract
Background: The high rate of periprocedural complications resulting from atherothrombotic embolization after percutaneous intervention in diseased saphenous vein grafts is reduced by distal microcirculatory protection using a balloon occlusion and aspiration system. Whether filter-based catheters, which offer the inherent advantages of maintained perfusion and ease of use, are as effective for this purpose has not been established.
Methods and results: A total of 651 patients undergoing percutaneous intervention of 682 saphenous vein graft lesions were prospectively randomized to distal protection with the filter-based FilterWire EX versus the GuardWire balloon occlusion and aspiration system. Device success was 95.5% and 97.2% with the FilterWire EX and GuardWire, respectively (P=0.25). Postprocedural measures of epicardial flow and angiographic complications were similar between the 2 groups, although bailout IIb/IIIa inhibitors were required slightly less frequently in the FilterWire EX group (0% versus 1.5%, P=0.03). The primary end point, the composite incidence of death, myocardial infarction, or target vessel revascularization at 30 days, occurred in 9.9% of FilterWire EX patients and 11.6% of GuardWire patients (difference [95% CI]=-1.7% [-6.4%, 3.1%]; P for superiority=0.53, P for noninferiority=0.0008).
Conclusions: Distal protection with the FilterWire EX may be safely used as an adjunct to percutaneous intervention of diseased saphenous vein grafts and, compared with distal protection with the GuardWire balloon occlusion and aspiration system, results in similar rates of major adverse cardiac events at 30 days.
Similar articles
-
Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts.Circulation. 2002 Mar 19;105(11):1285-90. Circulation. 2002. PMID: 11901037 Clinical Trial.
-
Six-month outcomes after percutaneous intervention for lesions in aortocoronary saphenous vein grafts using distal protection devices: results from the FIRE trial.Am Heart J. 2006 Apr;151(4):915.e1-7. doi: 10.1016/j.ahj.2005.09.018. Am Heart J. 2006. PMID: 16569562 Clinical Trial.
-
Influence of vessel diameter on the efficacy of distal protection devices during saphenous vein graft intervention.Am J Cardiol. 2005 Mar 1;95(5):651-4. doi: 10.1016/j.amjcard.2004.10.044. Am J Cardiol. 2005. PMID: 15721112 Clinical Trial.
-
Embolic protection devices in saphenous percutaneous intervention.EuroIntervention. 2009 May;5 Suppl D:D45-50. EuroIntervention. 2009. PMID: 19736070 Review.
-
Distal filter protection during saphenous vein graft stenting: technical and clinical correlates of efficacy.J Am Coll Cardiol. 2002 Nov 20;40(10):1882-8. doi: 10.1016/s0735-1097(02)02129-0. J Am Coll Cardiol. 2002. PMID: 12446075 Review.
Cited by
-
Percutaneous revascularization for ischemic nephropathy: the past, present, and future.Kidney Int. 2013 Jan;83(1):28-40. doi: 10.1038/ki.2012.363. Epub 2012 Nov 14. Kidney Int. 2013. PMID: 23151953 Free PMC article. Review.
-
Saphenous vein graft interventions.Curr Treat Options Cardiovasc Med. 2014 May;16(5):301. doi: 10.1007/s11936-014-0301-x. Curr Treat Options Cardiovasc Med. 2014. PMID: 24643432
-
Embolic protection device use in renal artery stent placement.J Vasc Interv Radiol. 2009 May;20(5):580-6. doi: 10.1016/j.jvir.2009.01.025. Epub 2009 Mar 27. J Vasc Interv Radiol. 2009. PMID: 19328725 Free PMC article. Clinical Trial.
-
Myocardial preservation during primary percutaneous intervention: It's time to rethink?Indian Heart J. 2021 Jul-Aug;73(4):395-403. doi: 10.1016/j.ihj.2021.07.008. Epub 2021 Jul 28. Indian Heart J. 2021. PMID: 34474749 Free PMC article. No abstract available.
-
Stenting of complex lesions: an overview.Nat Rev Cardiol. 2010 Sep;7(9):485-96. doi: 10.1038/nrcardio.2010.116. Nat Rev Cardiol. 2010. PMID: 20725106 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical