The potential of organic (electrospray- and atmospheric pressure chemical ionisation) mass spectrometric techniques coupled to liquid-phase separation for speciation analysis
- PMID: 12877203
- DOI: 10.1016/s0021-9673(03)00603-4
The potential of organic (electrospray- and atmospheric pressure chemical ionisation) mass spectrometric techniques coupled to liquid-phase separation for speciation analysis
Abstract
The use of mass spectrometry based on atmospheric pressure ionisation techniques (atmospheric pressure chemical ionisation, APCI, and electrospray ionisation, ESI) for speciation analysis is reviewed with emphasis on the literature published in and after 1999. This report accounts for the increasing interest that atmospheric pressure ionisation techniques, and in particular ESI, have found in the past years for qualitative and quantitative speciation analysis. In contrast to element-selective detectors, organic mass spectrometric techniques provide information on the intact metal species which can be used for the identification of unknown species (particularly with MS-MS detection) or the confirmation of the actual presence of species in a given sample. Due to the complexity of real samples, it is inevitable in all but the simplest cases to couple atmospheric pressure MS detection to a separation technique. Separation in the liquid phase (capillary electrophoresis or liquid chromatography in reversed phase, ion chromatographic or size-exclusion mode) is particularly suitable since the available techniques cover a very wide range of analyte polarities and molecular mass. Moreover, derivatisation can normally be avoided in liquid-phase separation. Particularly in complex environmental or biological samples, separation in one dimension is not sufficient for obtaining adequate resolution for all relevant species. In this case, multi-dimensional separation, based on orthogonal separation techniques, has proven successful. ESI-MS is also often used in parallel with inductively coupled plasma MS detection. This review is structured in two parts. In the first, the fundamentals of atmospheric pressure ionisation techniques are briefly reviewed. The second part of the review discusses recent applications including redox species, use of ESI-MS for structural elucidation of metal complexes, characterisation and quantification of small organometallic species with relevance to environment, health and food. Particular attention is given to the characterisation of biomolecules and metalloproteins (metallothioneins and phytochelatins) and to the investigation of the interaction of metals and biomolecules. Particularly in the latter field, ESI-MS is the ideal technique due to the softness of the ionisation process which allows to assume that the detected gas-phase ions are a true representation of the ions or ion-biomolecule complexes prevalent in solution. It is particularly this field, important to biochemistry, physiology and medical chemistry, where we can expect significant developments also in the future.
Similar articles
-
Capillary column supercritical fluid chromatography-atmospheric pressure ionisation mass spectrometry interface performance of atmospheric pressure chemical ionisation and electrospray ionisation.J Chromatogr A. 1999 Sep 3;855(1):317-27. doi: 10.1016/s0021-9673(99)00675-5. J Chromatogr A. 1999. PMID: 10514996
-
Comparison of electrospray ionisation, atmospheric pressure chemical ionisation and atmospheric pressure photoionisation for the identification of metabolites from labile artemisinin-based anti-malarial drugs using a QTRAP® mass spectrometer.Rapid Commun Mass Spectrom. 2012 Oct 30;26(20):2431-42. doi: 10.1002/rcm.6359. Rapid Commun Mass Spectrom. 2012. PMID: 22976210
-
Application of CE-ICP-MS and CE-ESI-MS in metalloproteomics: challenges, developments, and limitations.Anal Bioanal Chem. 2005 Oct;383(3):372-89. doi: 10.1007/s00216-005-3420-0. Epub 2005 Sep 13. Anal Bioanal Chem. 2005. PMID: 16158292 Review.
-
Separation of low-molecular mass organic acid-metal complexes by high-performance liquid chromatography.J Chromatogr A. 2004 Dec 3;1059(1-2):1-12. doi: 10.1016/j.chroma.2004.10.026. J Chromatogr A. 2004. PMID: 15628118 Review.
-
Hyphenated techniques for the characterization and quantification of metallothionein isoforms.Anal Bioanal Chem. 2002 Jul;373(6):441-53. doi: 10.1007/s00216-002-1350-7. Epub 2002 Jun 19. Anal Bioanal Chem. 2002. PMID: 12172679 Review.
Cited by
-
Iterative optimization of an ESI IT mass spectrometer using regular simplex and a multivariate target function representing the S/N ratio.J Am Soc Mass Spectrom. 2011 Jan;22(1):118-29. doi: 10.1007/s13361-010-0008-5. Epub 2011 Jan 28. J Am Soc Mass Spectrom. 2011. PMID: 21472550
-
Evaluation of signal and noise and identification of a suitable target function in the tuning of an ESI ion trap mass spectrometer by multivariate pattern recognition tools.J Am Soc Mass Spectrom. 2009 Oct;20(10):1859-67. doi: 10.1016/j.jasms.2009.06.011. Epub 2009 Jul 1. J Am Soc Mass Spectrom. 2009. PMID: 19660965
-
Identification of anionic supramolecular complexes of sulfonamide receptors with Cl-, NO3-, Br-, and I- by APCI-MS.J Am Soc Mass Spectrom. 2005 Aug;16(8):1377-83. doi: 10.1016/j.jasms.2005.04.008. J Am Soc Mass Spectrom. 2005. PMID: 27035012 Free PMC article.
-
Advances in structure elucidation of small molecules using mass spectrometry.Bioanal Rev. 2010 Dec;2(1-4):23-60. doi: 10.1007/s12566-010-0015-9. Epub 2010 Aug 21. Bioanal Rev. 2010. PMID: 21289855 Free PMC article.
-
Unlocking the potentials of Ustilago trichophora for up-cycling polyurethane-derived monomer 1,4-butanediol.Microb Biotechnol. 2024 Mar;17(3):e14384. doi: 10.1111/1751-7915.14384. Microb Biotechnol. 2024. PMID: 38454531 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous