(Micellar) electrokinetic chromatography: an interesting solution for the liquid phase separation dilemma
- PMID: 12877206
- DOI: 10.1016/s0021-9673(03)00503-x
(Micellar) electrokinetic chromatography: an interesting solution for the liquid phase separation dilemma
Abstract
High-performance liquid chromatography (HPLC) is a well-established method in modern analysis. The method is simple, very robust and is applicable to the majority of components to be analyzed in contrast to gas chromatography. Low efficiency and small peak capacity are sore points of HPLC when complex mixtures have to be separated. The reason for this dilemma is the small diffusion coefficient of the analytes in the liquid mobile phase compared to a gaseous phase. This review, complemented by exemplary calculated data and some latest results of our own research, illustrates the dilemma of liquid phase chromatography to achieve high efficiencies under reasonable conditions. It is shown that (micellar) electrokinetic chromatography, offering fast and efficient separations, is a very promising solution for this dilemma. Additional features of this method are possibilities of on-line analyte concentration, coupling to mass spectrometry and the easy change of selectivities by applying various separation additives. The pros and cons of electrokinetic chromatography are pointed out and some application examples are given.
Similar articles
-
Chiral Micellar Electrokinetic Chromatography.J Chromatogr A. 2020 Aug 30;1626:461383. doi: 10.1016/j.chroma.2020.461383. Epub 2020 Jul 1. J Chromatogr A. 2020. PMID: 32797856
-
Sweeping with electrokinetic injection and analyte focusing by micelle collapse in two-dimensional separation via integration of micellar electrokinetic chromatography with capillary zone electrophoresis.Anal Chem. 2011 Feb 15;83(4):1291-9. doi: 10.1021/ac102344y. Epub 2011 Jan 19. Anal Chem. 2011. PMID: 21247064
-
Micellar electrokinetic chromatography for high-performance analytical separation.Chem Rec. 2008;8(5):291-301. doi: 10.1002/tcr.20156. Chem Rec. 2008. PMID: 18956478 Review.
-
Robust analysis of the hydrophobic basic analytes loratadine and desloratadine in pharmaceutical preparations and biological fluids by sweeping-cyclodextrin-modified micellar electrokinetic chromatography.J Chromatogr A. 2013 Sep 27;1309:64-75. doi: 10.1016/j.chroma.2013.08.020. Epub 2013 Aug 9. J Chromatogr A. 2013. PMID: 23953618
-
Capillary separation: micellar electrokinetic chromatography.Annu Rev Anal Chem (Palo Alto Calif). 2009;2:99-120. doi: 10.1146/annurev.anchem.1.031207.113005. Annu Rev Anal Chem (Palo Alto Calif). 2009. PMID: 20636055 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous