Clinical Trial
. 2003 Jul;126(1):168-77; discussion 177-8.
doi: 10.1016/s0022-5223(03)00234-4.

Clinical and six-month angiographic evaluation of coronary arterial graft interrupted anastomoses by use of a self-closing clip device: a multicenter prospective clinical trial

Affiliations
Free article
Clinical Trial

Clinical and six-month angiographic evaluation of coronary arterial graft interrupted anastomoses by use of a self-closing clip device: a multicenter prospective clinical trial

Randall K Wolf et al. J Thorac Cardiovasc Surg. 2003 Jul.
Free article

Abstract

Objectives: To evaluate the safety and effectiveness of a self-closing surgical clip with an interrupted technique in left internal thoracic artery to left anterior descending artery bypass grafting.

Methods: Eighty-two patients were enrolled and treated (February 2000 through August 2001) in a prospective, nonrandomized, multicenter trial. Left internal thoracic artery to left anterior descending artery anastomoses were performed in 60 off-pump coronary artery bypasses (73%), 12 conventional coronary artery bypass grafting (15%), and 10 minimally invasive direct coronary artery bypass (12%) procedures. Angiograms (64 to 383 days, mean 200 days) were obtained on 63 patients (77%). Qualitative and quantitative angiographic assessment was performed by an independent core laboratory.

Results: The self-closing surgical clip was used for 82 left internal thoracic artery to left anterior descending artery interrupted anastomoses without the requirement for knot tying or primary suture management. Minimum left internal thoracic artery to left anterior descending artery anastomosis time was 3 minutes. There was one perioperative and one late death (both not heart related) and one reexploration for bleeding unrelated to the anastomotic site. FitzGibbon grades were as follows: A (n = 60, 95.2%), B (n = 3, 4.8%) including one kinked left internal thoracic artery, and O (n = 0, 0%). Quantitative analysis (n = 57) showed mean lumen diameters of left internal thoracic artery proximal to the anastomosis of 2.1 mm, at anastomosis of 2.0 mm, and in the left anterior descending artery distal to the anastomosis of 1.9 mm. The average ratio of the anastomosis to the left anterior descending artery diameter was 1.14 (0.45 to 1.93). Anastomotic stenosis as a percentage of average left internal thoracic artery to left anterior descending artery diameter was -2.3%, comparing favorably with results (23% to 24%) reported from the Patency, Outcomes, Economics, Minimally invasive direct coronary artery (POEM) bypass study.

Conclusions: The interrupted technique, facilitated by a self-closing anastomotic clip, yields favorable 6-month angiographic results when compared with other published studies.

PubMed Disclaimer

MeSH terms