Methodological concerns using intra-cortical pins to measure tibiofemoral kinematics
- PMID: 12879227
- DOI: 10.1007/s00167-003-0388-1
Methodological concerns using intra-cortical pins to measure tibiofemoral kinematics
Abstract
The complexity of human tibiofemoral joint motion is now better understood with the advancement of new methodologies to measure tibiofemoral kinematics in vivo. Marker clusters anchored to stainless steel bone pins inserted directly into the femur and tibia provide the most sensitive and accurate means for directly measuring skeletal tibiofemoral joint motion. Despite its invasiveness, this technique has been successful, although complications have been reported with the femoral pin and its insertion site. The purpose of this technical report is twofold: to review the difficulties with the femoral pin and its insertion site from a historical perspective, and to identify the load force required from biological tissue to permanently deform the pin. In addition, proposals in the advancement of this method are discussed in the context of reducing impingement with the femoral pin and the Iliotibial band. Because stainless steel exhibits plastic behaviour with no sharp yield point, Apex self-drilling/self-tapping bone pins underwent incremental loading on an Instron materials testing machine. Loads were transmitted perpendicular to the pin with the threads partially exposed and fully secured in vice. Since the accuracy of our combined stereophotogrammetry and Optoelectric motion analysis was less than 0.4 mm, it was decided that plastic deformation occurred after deflections of 0.4 mm. With exposed threads, deflections larger than 0.4 mm were observed at 150 N and 100 N when loads were applied at 15 mm and 20 mm from the vice (representative of where the tissue came in contact with the pin). Loads greater than 200 N produced deflections less than 0.2 mm when threads were fully inserted. The 90 Hz resonant frequency for the marker cluster-bone pin complex is beyond the spectrum of human movement and can be lowpass filtered. To reduce impingement and pin bending, one solution may be to implant pins with a shorter threaded section. By completely penetrating the bone, only the smooth surface of the pin is exposed which is more resistant to bending. Otherwise pins with larger diameters and longer longitudinal incisions about the femoral insertion site are an alternative. Lengthening the longitudinal incisions about the insertion site, and correctly aligning and inserting the femoral pin between the Iliotibial band and quadriceps tendon may diminish impingement. Performing dynamic open chain flexion and extension movements while on the operating table may aid in aligning the pin at the incision site. This may stretch the IT band and quadriceps tendon and may guide the femoral pin into a more optimal position prior to it being inserted into the cortex of the bone.
Similar articles
-
In situ comparison of A-mode ultrasound tracking system and skin-mounted markers for measuring kinematics of the lower extremity.J Biomech. 2018 Apr 27;72:134-143. doi: 10.1016/j.jbiomech.2018.03.007. Epub 2018 Mar 10. J Biomech. 2018. PMID: 29573792
-
Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo.Gait Posture. 2006 Oct;24(2):152-64. doi: 10.1016/j.gaitpost.2005.04.012. Epub 2005 Nov 2. Gait Posture. 2006. PMID: 16260140
-
[Hip centralising forces of the iliotibial tract with various femoral neck angles].Z Orthop Unfall. 2009 May-Jun;147(3):341-9. doi: 10.1055/s-2008-1039298. Epub 2009 Jun 23. Z Orthop Unfall. 2009. PMID: 19551586 German.
-
Biomechanics of the knee: methodological considerations in the in vivo kinematic analysis of the tibiofemoral and patellofemoral joint.Clin Biomech (Bristol). 1999 Nov;14(9):595-611. doi: 10.1016/s0268-0033(99)00015-7. Clin Biomech (Bristol). 1999. PMID: 10521643 Review.
-
Biomechanics of medial unicondylar in combination with patellofemoral knee arthroplasty.Knee. 2014;21 Suppl 1:S3-9. doi: 10.1016/S0968-0160(14)50002-6. Knee. 2014. PMID: 25382365 Review.
Cited by
-
A New Parameter of Hip Instability in Developmental Dysplasia of the Hip (DDH): Teardrop Distance.Front Surg. 2022 Jun 14;9:899960. doi: 10.3389/fsurg.2022.899960. eCollection 2022. Front Surg. 2022. PMID: 36034389 Free PMC article.
-
Lessons learned from the last 20 years of ACL-related in vivo-biomechanics research of the knee joint.Knee Surg Sports Traumatol Arthrosc. 2013 Apr;21(4):755-66. doi: 10.1007/s00167-012-1955-0. Epub 2012 Mar 23. Knee Surg Sports Traumatol Arthrosc. 2013. PMID: 22437657 Review.
-
Effects of Internal Fixation for Mid-Shaft Clavicle Fractures on Shoulder Kinematics During Humeral Elevations.Front Bioeng Biotechnol. 2021 Jul 22;9:710787. doi: 10.3389/fbioe.2021.710787. eCollection 2021. Front Bioeng Biotechnol. 2021. PMID: 34368104 Free PMC article.
-
A Direct Comparison of Biplanar Videoradiography and Optical Motion Capture for Foot and Ankle Kinematics.Front Bioeng Biotechnol. 2019 Aug 23;7:199. doi: 10.3389/fbioe.2019.00199. eCollection 2019. Front Bioeng Biotechnol. 2019. PMID: 31508415 Free PMC article.
-
AGREEMENT OF HIP KINEMATICS BETWEEN TWO TRACKING MARKER CONFIGURATIONS USED WITH THE CODA PELVIS DURING ERGONOMIC ROOFING TASKS.J Mech Med Biol. 2023 Jan 28;23(3):10.1142/s021951942350015x. doi: 10.1142/s021951942350015x. J Mech Med Biol. 2023. PMID: 37361026 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous