In vivo endoscopic tissue diagnostics based on spectroscopic absorption, scattering, and phase function properties
- PMID: 12880356
- DOI: 10.1117/1.1578494
In vivo endoscopic tissue diagnostics based on spectroscopic absorption, scattering, and phase function properties
Abstract
A fast spectroscopic system for superficial and local determination of the absorption and scattering properties of tissue (480 to 950 nm) is described. The probe can be used in the working channel of an endoscope. The scattering properties include the reduced scattering coefficient and a parameter of the phase function called gamma, which depends on its first two moments. The inverse problem algorithm is based on the fit of absolute reflectance measurements to cubic B-spline functions derived from the interpolation of a set of Monte Carlo simulations. The algorithm's robustness was tested with simulations altered with various amounts of noise. The method was also assessed on tissue phantoms of known optical properties. Finally, clinical measurements performed endoscopically in vivo in the stomach of human subjects are presented. The absorption and scattering properties were found to be significantly different in the antrum and in the fundus and are correlated with histopathologic observations. The method and the instrument show promise for noninvasive tissue diagnostics of various epithelia.
(c) 2003 Society of Photo-Optical Instrumentation Engineers.
Similar articles
-
In vivo determination of optical properties of normal and tumor tissue with white light reflectance and an empirical light transport model during endoscopy.J Biomed Opt. 2005 May-Jun;10(3):034018. doi: 10.1117/1.1921907. J Biomed Opt. 2005. PMID: 16229662 Clinical Trial.
-
In vitro determination of normal and neoplastic human brain tissue optical properties using inverse adding-doubling.Phys Med Biol. 2006 Apr 21;51(8):2011-27. doi: 10.1088/0031-9155/51/8/004. Epub 2006 Mar 30. Phys Med Biol. 2006. PMID: 16585842
-
Optical phantoms with adjustable subdiffusive scattering parameters.J Biomed Opt. 2015 Oct;20(10):105008. doi: 10.1117/1.JBO.20.10.105008. J Biomed Opt. 2015. PMID: 26473589
-
Influence of fiber optic probe geometry on the applicability of inverse models of tissue reflectance spectroscopy: computational models and experimental measurements.Appl Opt. 2006 Nov 1;45(31):8152-62. doi: 10.1364/ao.45.008152. Appl Opt. 2006. PMID: 17068558
-
Cost-effective diffuse reflectance spectroscopy device for quantifying tissue absorption and scattering in vivo.J Biomed Opt. 2008 Nov-Dec;13(6):060505. doi: 10.1117/1.3041500. J Biomed Opt. 2008. PMID: 19123646
Cited by
-
Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study.Phys Med Biol. 2005 Sep 7;50(17):4225-41. doi: 10.1088/0031-9155/50/17/021. Epub 2005 Aug 24. Phys Med Biol. 2005. PMID: 16177541 Free PMC article.
-
Diffuse optical microscopy for quantification of depth-dependent epithelial backscattering in the cervix.J Biomed Opt. 2016 Jun 1;21(6):66001. doi: 10.1117/1.JBO.21.6.066001. J Biomed Opt. 2016. PMID: 27251077 Free PMC article.
-
Instrument independent diffuse reflectance spectroscopy.J Biomed Opt. 2011 Jan-Feb;16(1):011010. doi: 10.1117/1.3524303. J Biomed Opt. 2011. PMID: 21280897 Free PMC article.
-
Diagnosis of vulvar lesions by non-invasive optical analysis: a pilot study.Rare Tumors. 2009 Jul 22;1(1):e8. doi: 10.4081/rt.2009.e8. Rare Tumors. 2009. PMID: 21139902 Free PMC article.
-
Influence of the phase function in generalized diffuse reflectance models: review of current formalisms and novel observations.J Biomed Opt. 2014;19(7):75005. doi: 10.1117/1.JBO.19.7.075005. J Biomed Opt. 2014. PMID: 25027000 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources