MEG and EEG in epilepsy
- PMID: 12881663
- DOI: 10.1097/00004691-200305000-00002
MEG and EEG in epilepsy
Abstract
Both EEG and magnetoencephalogram (MEG), with a time resolution of 1 ms or less, provide unique neurophysiologic data not obtainable by other neuroimaging techniques. MEG has now emerged as a mature clinical technology. While both EEG and MEG can be performed with more than 100 channels, MEG recordings with 100 to 300 channels are more easily done because of the time needed to apply a large number of EEG electrodes. EEG has the advantage of the long-term video EEG recordings, which facilitates extensive temporal sampling across all periods of the sleep/wake cycle. MEG and EEG seem to complement each other for the detection of interictal epileptiform discharges, because some spikes can be recorded only on MEG but not on EEG and vice versa. Most studies indicate that MEG seems to be more sensitive for neocortical spike sources. Both EEG and MEG source localizations show excellent agreement with invasive electrical recordings, clarify the spatial relationship between the irritative zone and structural lesions, and finally, attribute epileptic activity to lobar subcompartments in temporal lobe and to a lesser extent in extratemporal epilepsies. In temporal lobe epilepsy, EEG and MEG can differentiate between patients with mesial, lateral, and diffuse seizure onsets. MEG selectively detects tangential sources. EEG measures both radial and tangential activity, although the radial components dominate the EEG signals at the scalp. Thus, while EEG provides more comprehensive information, it is more complicated to model due to considerable influences of the shape and conductivity of the volume conductor. Dipole localization techniques favor MEG due to the higher accuracy of MEG source localization compared to EEG when using the standard spherical head shape model. However, if special care is taken to address the above issues and enhance the EEG, the localization accuracy of EEG and MEG actually are comparable, although these surface EEG analytic techniques are not typically approved for clinical use in the United States. MEG dipole analysis is approved for clinical use and thus gives information that otherwise usually requires invasive intracranial EEG monitoring. There are only a few dozen whole head MEG units in operation in the world. While EEG is available in every hospital, specialized EEG laboratories capable of source localization techniques are nearly as scarce as MEG facilities. The combined use of whole-head MEG systems and multichannel EEG in conjunction with advanced source modeling techniques is an area of active development and will allow a better noninvasive characterization of the irritative zone in presurgical epilepsy evaluation. Finally, additional information on epilepsy may be gathered by either MEG or EEG analysis of data beyond the usual bandwidths used in clinical practice, namely by analysis of activity at high frequencies and near-DC activity.
Similar articles
-
Controversies in clinical neurophysiology. MEG is superior to EEG in the localization of interictal epileptiform activity: Con.Clin Neurophysiol. 2004 May;115(5):1010-20. doi: 10.1016/j.clinph.2003.12.010. Clin Neurophysiol. 2004. PMID: 15066524 Review.
-
Magnetoencephalography in focal epilepsy.Epilepsia. 2000;41 Suppl 3:S39-47. doi: 10.1111/j.1528-1157.2000.tb01533.x. Epilepsia. 2000. PMID: 11001335 Review.
-
Magnetoencephalography in presurgical epilepsy evaluation.Neurosurg Rev. 2002 Jun;25(3):141-59; discussion 160-1. doi: 10.1007/s10143-001-0197-2. Neurosurg Rev. 2002. PMID: 12135228 Review.
-
Interictal and ictal source localization for epilepsy surgery using high-density EEG with MEG: a prospective long-term study.Brain. 2019 Apr 1;142(4):932-951. doi: 10.1093/brain/awz015. Brain. 2019. PMID: 30805596 Free PMC article.
-
Magnetoencephalography-directed surgery in patients with neocortical epilepsy.J Neurosurg. 2002 Oct;97(4):865-73. doi: 10.3171/jns.2002.97.4.0865. J Neurosurg. 2002. PMID: 12405375 Clinical Trial.
Cited by
-
Physiological and pathological neuronal connectivity in the living human brain based on intracranial EEG signals: the current state of research.Front Netw Physiol. 2023 Nov 30;3:1297345. doi: 10.3389/fnetp.2023.1297345. eCollection 2023. Front Netw Physiol. 2023. PMID: 38107334 Free PMC article. Review.
-
Resting state brain activity in patients with migraine: a magnetoencephalography study.J Headache Pain. 2015;16:525. doi: 10.1186/s10194-015-0525-5. Epub 2015 May 7. J Headache Pain. 2015. PMID: 25968099 Free PMC article.
-
Assessing the localization accuracy and clinical utility of electric and magnetic source imaging in children with epilepsy.Clin Neurophysiol. 2019 Apr;130(4):491-504. doi: 10.1016/j.clinph.2019.01.009. Epub 2019 Jan 31. Clin Neurophysiol. 2019. PMID: 30771726 Free PMC article.
-