Optimal defibrillation response intervals for maximum out-of-hospital cardiac arrest survival rates
- PMID: 12883512
- DOI: 10.1067/mem.2003.266
Optimal defibrillation response intervals for maximum out-of-hospital cardiac arrest survival rates
Abstract
Study objective: Many centers optimize their emergency medical services (EMS) systems to achieve a target defibrillation response interval of "call received by dispatch" to "arrival at scene by responder with defibrillator" in 8 minutes or less for at least 90% of cardiac arrest cases. The objective of this study was to analyze survival as a function of time to test the evidence for this standard.
Methods: This prospective cohort study included all adult, cardiac etiology, out-of-hospital cardiac arrest cases from phases I and II of the Ontario Prehospital Advanced Life Support (OPALS) study. Patients in the 21 Ontario study communities received a basic life support level of care with defibrillation by ambulance and firefighters but no advanced life support. Survival was plotted as a function of the defibrillation response interval. The equation of the curve, generated by means of logistic regression, was used to estimate survival at various defibrillation response interval cutoff points.
Results: From January 1, 1991, to December 31, 1997, there were 392 (4.2%) survivors overall among the 9,273 patients treated. The defibrillation response interval mean was 6.2 minutes, and the 90th percentile was 9.3 minutes. There was a steep decrease in the first 5 minutes of the survival curve, beyond which the slope gradually leveled off. Controlling for known covariates, the decrement in the odds of survival with increasing response interval was 0.77 per minute (95% confidence interval 0.74 to 0.83). The survival function predicts, for successive 90th percentile cutoff points, both survival rates and additional lives saved per year in the OPALS communities compared with the 8-minute standard: 9 minutes (4.6%; -18 lives), 8 minutes (5.9%; 0 lives), 7 minutes (7.5%; 23 lives), 6 minutes (9.5%; 51 lives), and 5 minutes (12.0%; 86 lives).
Conclusion: The 8-minute target established in many communities is not supported by our data as the optimal EMS defibrillation response interval for cardiac arrest. EMS system leaders should consider the effect of decreasing the 90th percentile defibrillation response interval to less than 8 minutes.
Comment in
-
The eight-minute defibrillation response interval debunked: or is it?Ann Emerg Med. 2003 Aug;42(2):251-5. doi: 10.1067/mem.2003.267. Ann Emerg Med. 2003. PMID: 12883513 Review. No abstract available.
Similar articles
-
Improved out-of-hospital cardiac arrest survival through the inexpensive optimization of an existing defibrillation program: OPALS study phase II. Ontario Prehospital Advanced Life Support.JAMA. 1999 Apr 7;281(13):1175-81. doi: 10.1001/jama.281.13.1175. JAMA. 1999. PMID: 10199426 Clinical Trial.
-
Modifiable factors associated with improved cardiac arrest survival in a multicenter basic life support/defibrillation system: OPALS Study Phase I results. Ontario Prehospital Advanced Life Support.Ann Emerg Med. 1999 Jan;33(1):44-50. doi: 10.1016/s0196-0644(99)70415-4. Ann Emerg Med. 1999. PMID: 9867885 Clinical Trial.
-
Cardiac arrest witnessed by emergency medical services personnel: descriptive epidemiology, prodromal symptoms, and predictors of survival. OPALS study group.Ann Emerg Med. 2000 Feb;35(2):138-46. Ann Emerg Med. 2000. PMID: 10650231
-
The eight-minute defibrillation response interval debunked: or is it?Ann Emerg Med. 2003 Aug;42(2):251-5. doi: 10.1067/mem.2003.267. Ann Emerg Med. 2003. PMID: 12883513 Review. No abstract available.
-
A cumulative meta-analysis of the effectiveness of defibrillator-capable emergency medical services for victims of out-of-hospital cardiac arrest.Ann Emerg Med. 1999 Oct;34(4 Pt 1):517-25. Ann Emerg Med. 1999. PMID: 10499952
Cited by
-
An innovative Hearing AED alarm system shortens delivery time of automated external defibrillator - A randomized controlled simulation study.Resusc Plus. 2024 Sep 20;20:100781. doi: 10.1016/j.resplu.2024.100781. eCollection 2024 Dec. Resusc Plus. 2024. PMID: 39380663 Free PMC article.
-
Reducing Time to First on Scene: An Ambulance-Community First Responder Scheme.Emerg Med Int. 2016;2016:1915895. doi: 10.1155/2016/1915895. Epub 2016 Mar 31. Emerg Med Int. 2016. PMID: 27119024 Free PMC article.
-
Evaluating emergency medical service performance measures.Health Care Manag Sci. 2010 Jun;13(2):124-36. doi: 10.1007/s10729-009-9115-x. Health Care Manag Sci. 2010. PMID: 20629415
-
Collapse-to-emergency medical service cardiopulmonary resuscitation interval and outcomes of out-of-hospital cardiopulmonary arrest: a nationwide observational study.Crit Care. 2011;15(3):R120. doi: 10.1186/cc10219. Epub 2011 May 5. Crit Care. 2011. PMID: 21545735 Free PMC article.
-
The impact of locked cabinets for automated external defibrillators (AEDs) on cardiac arrest and AED outcomes: A scoping review.Resusc Plus. 2024 Oct 1;20:100791. doi: 10.1016/j.resplu.2024.100791. eCollection 2024 Dec. Resusc Plus. 2024. PMID: 39411744 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous