Critical review of non-invasive respiratory monitoring in medical care

M Folke et al. Med Biol Eng Comput. 2003 Jul.

Abstract

Respiratory failure can be difficult to predict. It can develop into a life-threatening condition in just a few minutes, or it can build up more slowly. Thus continuous monitoring of respiratory activity should be mandatory in clinical, high-risk situations, and appropriate monitoring equipment could be life-saving. The review considers non-invasive methods and devices claimed to provide information about respiratory rate or depth, or gas exchange. Methods are categorised into those responding to movement, volume and tissue composition detection; air flow; and blood gas concentration. The merits and limitations of the methods and devices are analysed, considering information content and their ability to minimise the rate of false alarms and false non-alarms. It is concluded that the field of non-invasive respiratory monitoring is still in an exploratory phase, with numerous reports on specific device solutions but less work on evaluation and adaptation to clinical requirements. Convincing evidence of the clinical usefulness of respiratory monitors is still lacking. Devices responding only to respiratory rate, and lacking information about actual gas exchange, will have limited clinical value. Furthermore, enhancement in specificity and sensitivity to avoid false alarms and non-alarms will be necessary to meet clinical requirements. Miniature CO2 sensors are identified as one route towards substantial improvement.

PubMed Disclaimer

References

    1. Chest. 1985 May;87(5):577-9 - PubMed
    1. J Clin Monit Comput. 1999 Jul;15(5):295-8 - PubMed
    1. Med Biol Eng Comput. 1989 Jul;27(4):423-5 - PubMed
    1. Am Rev Respir Dis. 1988 Dec;138(6):1625-42 - PubMed
    1. Adv Nurse Pract. 2002 Mar;10(3):48-53; quiz 53-4 - PubMed