Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 1992;18(8):479-84.
doi: 10.1007/BF01708585.

Differential lung ventilation with a double-lumen tracheostomy tube in unilateral refractory atelectasis

Affiliations
Case Reports

Differential lung ventilation with a double-lumen tracheostomy tube in unilateral refractory atelectasis

A Alberti et al. Intensive Care Med. 1992.

Abstract

Two patients with refractory hypoxemia due to unilateral lung atelectasis were treated with differential lung ventilation (DLV) through a Robertshaw-type, double-lumen tracheostomy tube. DLV was applied using two non-synchronized ventilators and maintained for 6 and 3 days, respectively. Ventilator settings were chosen in accord to the clinical, laboratory and chest X-rays results. Particularly, tidal volume and PEEP were set to avoid excessively high alveolar pressure and to obtain the highest possible value of compliance. We investigated the mechanical properties of the two lungs separately by measuring airway pressure and compliance of each lung before the beginning of DLV and at 0, 5, 24, and 48 h after. Initially we observed in both patients very low values of compliance (7-9 cm H2O/l) and a significant level of PEEPi (12-8 cm H2O) of the diseased lung, whereas PEEPi in the healthy lung was negligible. The clinical improvement was assessed by sequential chest X-rays and by significant improvement of arterial blood gas and PaO2/FiO2 ratios and was associated with a progressive increase of compliance (24-22 cm H2O/l) and by a fall of PEEPi levels (5-4 cm H2O) of the diseased lung. We also observed an improvement of SvO2, O2AVI, PVRI and Qva/Qt values (Case 1). The tracheostomy tube used to apply DLV was very reliable, allowing easy nursing care and selective bronchial aspirations. We conclude that DLV is a very useful technique in unilateral lung pathology, and it can be a life saving procedure in selected patients, by supplying volume and PEEP more efficiently to the affected lung.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Am Rev Respir Dis. 1989 Jul;140(1):10-6 - PubMed
    1. J Clin Invest. 1972 Sep;51(9):2315-23 - PubMed
    1. Intensive Care Med. 1989;15(7):458-63 - PubMed
    1. J Trauma. 1985 Aug;25(8):766-70 - PubMed
    1. J Appl Physiol (1985). 1985 Aug;59(2):647-52 - PubMed

Publication types

MeSH terms

LinkOut - more resources