Comprehensive quality assurance for stereotactic radiosurgery treatments
- PMID: 12894984
- DOI: 10.1088/0031-9155/48/14/402
Comprehensive quality assurance for stereotactic radiosurgery treatments
Abstract
We have used a commercially available high precision Lucy phantom to perform comprehensive quality assurance for stereotactic radiosurgery treatments. The quantitative evaluation of system uncertainties included imaging, planning and treatment delivery systems. The quality assurance tests showed that the well-defined targets were identified to within +/-1 mm in all the imaging modalities. The pre-known target volumes were reproduced within 2 cm3 in both MR and CT. The planned target was delivered within 2% of the prescribed dose and to within 2 mm accuracy. The inaccuracy in the isocentre position at the Linac was less than 1.2 mm. The maximum error observed in the depth helmet was 0.5 mm and the overall uncertainty was within 0.23 mm. We have also established a quality assurance program based on the study and proposed the tolerance and the frequency of the tests required to be carried out. The tests were carried out using a Radionics planning system and delivered on a Varian Clinac 2100 linear accelerator machine. These tests also established a base line for future comparisons.
Similar articles
-
Commissioning and quality assurance of a commercial stereotactic treatment-planning system for extracranial IMRT.J Appl Clin Med Phys. 2006 Winter;7(1):21-34. doi: 10.1120/jacmp.v7i1.2125. Epub 2006 Feb 15. J Appl Clin Med Phys. 2006. PMID: 16518314 Free PMC article.
-
Geometrical accuracy of the Novalis stereotactic radiosurgery system for trigeminal neuralgia.J Neurosurg. 2004 Nov;101 Suppl 3:351-5. J Neurosurg. 2004. PMID: 15537189
-
Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system.Med Phys. 2003 Jun;30(6):1198-210. doi: 10.1118/1.1573792. Med Phys. 2003. PMID: 12852544
-
[Technologic developments in radiotherapy and stereotactic radiosurgery].Neurochirurgie. 2001 May;47(2-3 Pt 2):260-6. Neurochirurgie. 2001. PMID: 11404704 Review. French.
-
Magnetic resonance imaging for brain stereotactic radiotherapy : A review of requirements and pitfalls.Strahlenther Onkol. 2020 May;196(5):444-456. doi: 10.1007/s00066-020-01604-0. Epub 2020 Mar 23. Strahlenther Onkol. 2020. PMID: 32206842 Free PMC article. Review.
Cited by
-
A quality assurance method with submillimeter accuracy for stereotactic linear accelerators.J Appl Clin Med Phys. 2010 Dec 8;12(1):3365. doi: 10.1120/jacmp.v12i1.3365. J Appl Clin Med Phys. 2010. PMID: 21330986 Free PMC article.
-
Monte Carlo Dose Calculation - A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions.J Med Phys. 2022 Jan-Mar;47(1):99-104. doi: 10.4103/jmp.jmp_123_21. Epub 2022 Mar 31. J Med Phys. 2022. PMID: 35548031 Free PMC article.
-
Head to head comparison of two commercial phantoms used for SRS QA.J Radiosurg SBRT. 2016;4(3):213-223. J Radiosurg SBRT. 2016. PMID: 29296446 Free PMC article.
-
Historical Progress of Stereotactic Radiation Surgery.J Med Phys. 2023 Oct-Dec;48(4):312-327. doi: 10.4103/jmp.jmp_62_23. Epub 2023 Dec 5. J Med Phys. 2023. PMID: 38223793 Free PMC article. Review.
-
Isocenter verification for linac-based stereotactic radiation therapy: review of principles and techniques.J Appl Clin Med Phys. 2011 Nov 15;12(4):3645. doi: 10.1120/jacmp.v12i4.3645. J Appl Clin Med Phys. 2011. PMID: 22089022 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources