Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: preliminary phantom study
- PMID: 12906186
- DOI: 10.1118/1.1582470
Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: preliminary phantom study
Abstract
Cone beam computed tomography (CBCT) has been investigated in the past two decades due to its potential advantages over a fan beam CT. These advantages include (a) great improvement in data acquisition efficiency, spatial resolution, and spatial resolution uniformity, (b) substantially better utilization of x-ray photons generated by the x-ray tube compared to a fan beam CT, and (c) significant advancement in clinical three-dimensional (3D) CT applications. However, most studies of CBCT in the past are focused on cone beam data acquisition theories and reconstruction algorithms. The recent development of x-ray flat panel detectors (FPD) has made CBCT imaging feasible and practical. This paper reports a newly built flat panel detector-based CBCT prototype scanner and presents the results of the preliminary evaluation of the prototype through a phantom study. The prototype consisted of an x-ray tube, a flat panel detector, a GE 8800 CT gantry, a patient table and a computer system. The prototype was constructed by modifying a GE 8800 CT gantry such that both a single-circle cone beam acquisition orbit and a circle-plus-two-arcs orbit can be achieved. With a circle-plus-two-arcs orbit, a complete set of cone beam projection data can be obtained, consisting of a set of circle projections and a set of arc projections. Using the prototype scanner, the set of circle projections were acquired by rotating the x-ray tube and the FPD together on the gantry, and the set of arc projections were obtained by tilting the gantry while the x-ray tube and detector were at the 12 and 6 o'clock positions, respectively. A filtered backprojection exact cone beam reconstruction algorithm based on a circle-plus-two-arcs orbit was used for cone beam reconstruction from both the circle and arc projections. The system was first characterized in terms of the linearity and dynamic range of the detector. Then the uniformity, spatial resolution and low contrast resolution were assessed using different phantoms mainly in the central plane of the cone beam reconstruction. Finally, the reconstruction accuracy of using the circle-plus-two-arcs orbit and its related filtered backprojection cone beam volume CT reconstruction algorithm was evaluated with a specially designed disk phantom. The results obtained using the new cone beam acquisition orbit and the related reconstruction algorithm were compared to those obtained using a single-circle cone beam geometry and Feldkamp's algorithm in terms of reconstruction accuracy. The results of the study demonstrate that the circle-plus-two-arcs cone beam orbit is achievable in practice. Also, the reconstruction accuracy of cone beam reconstruction is significantly improved with the circle-plus-two-arcs orbit and its related exact CB-FPB algorithm, as compared to using a single circle cone beam orbit and Feldkamp's algorithm.
Similar articles
-
A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.Phys Med Biol. 2006 Feb 21;51(4):855-74. doi: 10.1088/0031-9155/51/4/007. Epub 2006 Jan 25. Phys Med Biol. 2006. PMID: 16467583
-
A cone beam filtered backprojection (CB-FBP) reconstruction algorithm for a circle-plus-two-arc orbit.Med Phys. 2001 Jun;28(6):1042-55. doi: 10.1118/1.1376444. Med Phys. 2001. PMID: 11439474
-
Physical phantom studies of helical cone-beam CT with exact reconstruction.Med Phys. 2012 Aug;39(8):4695-704. doi: 10.1118/1.4736535. Med Phys. 2012. PMID: 22894394
-
[On the way to isotopic spatial resolution: technical principles and applications of 16-slice CT].Radiologe. 2005 Jul;45(7):608-17. doi: 10.1007/s00117-003-0944-1. Radiologe. 2005. PMID: 16059657 Review. German.
-
Use of cone-beam computed tomography for advanced imaging of the equine patient.Equine Vet J. 2021 Sep;53(5):872-885. doi: 10.1111/evj.13473. Epub 2021 Jul 14. Equine Vet J. 2021. PMID: 34053096 Review.
Cited by
-
Exact Weighted-FBP Algorithm for Three-Orthogonal-Circular Scanning Reconstruction.Sensors (Basel). 2009;9(6):4606-14. doi: 10.3390/s90604606. Epub 2009 Jun 12. Sensors (Basel). 2009. PMID: 22408544 Free PMC article.
-
Preliminary exploration of response the course of radiotherapy for stage III non-small cell lung cancer based on longitudinal CT radiomics features.Eur J Radiol Open. 2021 Dec 16;9:100391. doi: 10.1016/j.ejro.2021.100391. eCollection 2022. Eur J Radiol Open. 2021. PMID: 34977279 Free PMC article.
-
Measurement of breast tissue composition with dual energy cone-beam computed tomography: a postmortem study.Med Phys. 2013 Jun;40(6):061902. doi: 10.1118/1.4802734. Med Phys. 2013. PMID: 23718593 Free PMC article.
-
Compensating the intensity fall-off effect in cone-beam tomography by an empirical weight formula.Appl Opt. 2008 Nov 10;47(32):6033-9. doi: 10.1364/ao.47.006033. Appl Opt. 2008. PMID: 19002227 Free PMC article.
-
Computed tomography for imaging the breast.J Mammary Gland Biol Neoplasia. 2006 Apr;11(2):103-11. doi: 10.1007/s10911-006-9017-1. J Mammary Gland Biol Neoplasia. 2006. PMID: 17053979