Chronic performance of steroid-eluting epicardial leads in a growing pediatric population: a 10-year comparison
- PMID: 12914623
- DOI: 10.1046/j.1460-9592.2003.t01-1-00212.x
Chronic performance of steroid-eluting epicardial leads in a growing pediatric population: a 10-year comparison
Abstract
Patient size and congenital heart defects complicate pacemaker therapy in children favoring an initial epicardial approach. Steroid-eluting (SE) epicardial (EPI) leads maintain stable, low pacing thresholds in the short-term when compared to the nonsteroid (NSE) epicardial (EPI) leads. The purpose of this study was to evaluate chronic, 10-year performance of SE leads in growing children compared with NSE EPI leads implanted during the same time interval. From 1990 to 2000, 35 patients (age 1 month to 18 year, median 3 years), 28 with and 7 without congenital heart disease (CHD) received 51 SE leads: 27 ventricular and 24 atrial. NSE leads were implanted in 27 patients (age 1-28 years, median 8 years), 24 with and 3 without CHD: 27 ventricular and 1 atrial. Pacing lead threshold, impedance, and energy were measured at implant and during a 10-year follow-up. Unpaired t-test showed that impedance remained stable for all leads with lower mean values for the SE(376 +/- 55 vs 443 +/- 109 Omega) (P = NS). The mean energy requirement for SE leads at 10 years(1.2 +/- 0.9 microJ)was significantly lower than for NSE(4.4 +/- 5.5 microJ) (P < 0.05). At 2.5-V output, chronic thresholds for SE leads did not significantly differ from implant values for atrial (0.08 vs 0.09 ms) or ventricular (0.08 vs 0.08 ms) sites. There were no differences in SE lead performances among patients with or without CHD. Fracture or dislodgement occurred in two SE (4%) and four NSE (14%) leads. SE outperform NSE EPI leads and show stable, chronic low thresholds over time in all growing children.
Similar articles
-
Steroid-eluting epicardial pacing electrodes: six year experience of pacing thresholds in a growing pediatric population.Pacing Clin Electrophysiol. 1997 Dec;20(12 Pt 1):2943-8. doi: 10.1111/j.1540-8159.1997.tb05464.x. Pacing Clin Electrophysiol. 1997. PMID: 9455755
-
A 12-year experience of bipolar steroid-eluting epicardial pacing leads in children.Ann Thorac Surg. 2008 May;85(5):1704-11. doi: 10.1016/j.athoracsur.2008.02.016. Ann Thorac Surg. 2008. PMID: 18442570
-
Efficacy of prophylactic epicardial pacing leads in children and young adults.Ann Thorac Surg. 2004 Jul;78(1):197-202; discussion 202-3. doi: 10.1016/j.athoracsur.2004.02.008. Ann Thorac Surg. 2004. PMID: 15223427 Review.
-
Epicardial left ventricular leads via minimally invasive technique: a role of steroid eluting leads.J Cardiothorac Surg. 2017 Nov 8;12(1):95. doi: 10.1186/s13019-017-0659-4. J Cardiothorac Surg. 2017. PMID: 29117867 Free PMC article.
-
A comparison of steroid-eluting epicardial versus transvenous pacing leads in children.J Card Surg. 2000 Sep-Oct;15(5):323-9. doi: 10.1111/j.1540-8191.2000.tb00465.x. J Card Surg. 2000. PMID: 11599824
Cited by
-
A hybrid form of cardiac resynchronisation therapy in patients with failing systemic right ventricles.J Interv Card Electrophysiol. 2008 Dec;23(3):229-33. doi: 10.1007/s10840-008-9296-0. Epub 2008 Oct 4. J Interv Card Electrophysiol. 2008. PMID: 18836823
-
Single chamber permanent epicardial pacing for children with congenital heart disease after surgical repair.J Cardiothorac Surg. 2016 Apr 12;11(1):61. doi: 10.1186/s13019-016-0439-6. J Cardiothorac Surg. 2016. PMID: 27067028 Free PMC article.
-
Minimally Invasive Implantation of a Micropacemaker Into the Pericardial Space.Circ Arrhythm Electrophysiol. 2018 Jul;11(7):e006307. doi: 10.1161/CIRCEP.118.006307. Circ Arrhythm Electrophysiol. 2018. PMID: 29945929 Free PMC article.
-
Fractally coated myocardial pacemaker leads in children.J Interv Card Electrophysiol. 2005 Oct;14(1):37-43. doi: 10.1007/s10840-005-3409-9. J Interv Card Electrophysiol. 2005. PMID: 16311937
-
New Guidelines of Pediatric Cardiac Implantable Electronic Devices: What Is Changing in Clinical Practice?J Cardiovasc Dev Dis. 2024 Mar 27;11(4):99. doi: 10.3390/jcdd11040099. J Cardiovasc Dev Dis. 2024. PMID: 38667717 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous