Brain responses to micro-machined silicon devices
- PMID: 12914963
- DOI: 10.1016/s0006-8993(03)03023-3
Brain responses to micro-machined silicon devices
Abstract
Micro-machined neural prosthetic devices can be designed and fabricated to permit recording and stimulation of specific sites in the nervous system. Unfortunately, the long-term use of these devices is compromised by cellular encapsulation. The goals of this study were to determine if device size, surface characteristics, or insertion method affected this response. Devices with two general designs were used. One group had chisel-shaped tips, sharp angular corners, and surface irregularities on the micrometer size scale. The second group had rounded corners, and smooth surfaces. Devices of the first group were inserted using a microprocessor-controlled inserter. Devices of the second group were inserted by hand. Comparisons were made of responses to the larger devices in the first group with devices from the second group. Responses were assessed 1 day and 1, 2, 4, 6, and 12 weeks after insertions. Tissues were immunochemically labeled for glial fibrillary acidic protein (GFAP) or vimentin to identify astrocytes, or for ED1 to identify microglia. For the second comparison devices from the first group with different cross-sectional areas were analyzed. Similar reactive responses were observed following insertion of all devices; however, the volume of tissue involved at early times, <1 week, was proportional to the cross-sectional area of the devices. Responses observed after 4 weeks were similar for all devices. Thus, the continued presence of devices promotes formation of a sheath composed partly of reactive astrocytes and microglia. Both GFAP-positive and -negative cells were adherent to all devices. These data indicate that device insertion promotes two responses-an early response that is proportional to device size and a sustained response that is independent of device size, geometry, and surface roughness. The early response may be associated with the amount of damage generated during insertion. The sustained response is more likely due to tissue-device interactions.
Similar articles
-
Dexamethasone treatment reduces astroglia responses to inserted neuroprosthetic devices in rat neocortex.Exp Neurol. 2005 Aug;194(2):289-300. doi: 10.1016/j.expneurol.2004.08.037. Exp Neurol. 2005. PMID: 16022859
-
Cerebral astrocyte response to micromachined silicon implants.Exp Neurol. 1999 Mar;156(1):33-49. doi: 10.1006/exnr.1998.6983. Exp Neurol. 1999. PMID: 10192775
-
Extensive and long-lasting changes of glial cells following transection of the postcommissural fornix in the adult rat.Glia. 1994 Feb;10(2):89-100. doi: 10.1002/glia.440100203. Glia. 1994. PMID: 8168870
-
A rapid replacement of vimentin-containing radial glia by glial fibrillary acidic protein-containing astrocytes in transplanted telencephalon.J Neural Transplant Plast. 1997 Jan-Mar;6(1):21-9. doi: 10.1155/NP.1997.21. J Neural Transplant Plast. 1997. PMID: 8959548 Free PMC article.
-
Co-expression of glial fibrillary acidic protein and vimentin in reactive astrocytes following brain injury in rats.Brain Res. 1991 Dec 6;566(1-2):333-6. doi: 10.1016/0006-8993(91)91720-l. Brain Res. 1991. PMID: 1814551
Cited by
-
Hybrid Multisite Silicon Neural Probe with Integrated Flexible Connector for Interchangeable Packaging.Sensors (Basel). 2021 Apr 8;21(8):2605. doi: 10.3390/s21082605. Sensors (Basel). 2021. PMID: 33917654 Free PMC article.
-
Titania nanotube arrays as interfaces for neural prostheses.Mater Sci Eng C Mater Biol Appl. 2015 Apr;49:735-745. doi: 10.1016/j.msec.2015.01.077. Epub 2015 Jan 26. Mater Sci Eng C Mater Biol Appl. 2015. PMID: 25687003 Free PMC article.
-
Neural Recording and Modulation Technologies.Nat Rev Mater. 2017 Feb;2(2):16093. doi: 10.1038/natrevmats.2016.93. Epub 2017 Jan 4. Nat Rev Mater. 2017. PMID: 31448131 Free PMC article.
-
Commonly Overlooked Factors in Biocompatibility Studies of Neural Implants.Adv Sci (Weinh). 2023 Feb;10(6):e2205095. doi: 10.1002/advs.202205095. Epub 2023 Jan 3. Adv Sci (Weinh). 2023. PMID: 36596702 Free PMC article. Review.
-
Carbohydrate based biomaterials for neural interface applications.J Mater Chem B. 2022 Jun 29;10(25):4714-4740. doi: 10.1039/d2tb00584k. J Mater Chem B. 2022. PMID: 35702979 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous