Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 May 15;75(10):2251-5.
doi: 10.1021/ac026415f.

Selective measurement of ultratrace methylmercury in fish by flow injection on-line microcolumn displacement sorption preconcentration and separation coupled with electrothermal atomic absorption spectrometry

Affiliations

Selective measurement of ultratrace methylmercury in fish by flow injection on-line microcolumn displacement sorption preconcentration and separation coupled with electrothermal atomic absorption spectrometry

Xiu-Ping Yan et al. Anal Chem. .

Abstract

A novel nonchromatographic speciation technique for ultratrace methylmercury in biological materials was developed by flow injection microcolumn displacement sorption preconcentration and separation coupled on-line with electrothermal atomic absorption spectrometry (ETAAS). In the developed technique, Cu(II) was first on-line complexed with diethyldithiocarbamate (DDTC), and the resultant Cu-DDTC was presorbed onto a microcolumn packed with the sorbent from a cigarette filter. Selective preconcentration of methylmercury (MeHg) in the presence of Hg(II), ethylmercury (EtHg), and phenylmercury (PhHg) was achieved at pH 6.8 through loading the sample solution onto the microcolumn due to a displacement reaction between MeHg and the presorbed Cu-DDTC. The retained MeHg was subsequently eluted with 50 microL of ethanol and on-line determined by ETAAS. Interferences from coexisting heavy metal ions with lower stability of their DDTC complexes relative to Cu-DDTC were minimized without the need of any masking reagents. No interferences from 5.5 mg L(-1) Cu(II), 4.5 mg L(-1) Cd(II), 2.5 mg L(-1) Cr(III), 3 mg L(-1) Fe(III), 10 mg L(-1) Ni(II), 10 mg L(-1) Pb(II), and at least 25 mg L(-1) Zn(II) were observed for the determination of MeHg at the 50 ng L(-1) level (as Hg). With the consumption of only 3.4 mL of sample solution, an enhancement factor of 75, a detection limit of 6.8 ng L(-1) (as Hg) in the digest (corresponding to 3.4 ng g(-1) in original solid sample for a final 50 mL of digest of 0.1 g of solid material), and a precision (RSD, n = 13) of 2.3% for the determination of methylmercury at the 50 ng L(-1) (as Hg) level were achieved at a sample throughput of 30 samples h(-1). The recoveries of methylmercury spike in real fish samples ranged from 97 to 108%. The developed technique was validated by determination of methylmercury in a certified reference material (DORM-2, dogfish muscle), and was shown to be useful for the determination of methylmercury in real fish samples.

PubMed Disclaimer

Similar articles

Publication types

Substances

LinkOut - more resources