Barcode technology: its role in increasing the safety of blood transfusion
- PMID: 12919421
- DOI: 10.1046/j.1537-2995.2003.00428.x
Barcode technology: its role in increasing the safety of blood transfusion
Abstract
Background: Incorrect blood component transfusion is the most frequent serious incident associated with transfusion. Errors responsible for these incidents frequently involve patient misidentification.
Study design and methods: This study evaluated a barcode patient identification system involving hand-held computers for blood sample collection for compatibility testing and the administration of blood. Audit of practice was carried out before and after its introduction.
Results: The baseline audit revealed poor practice, particularly in patient identification. Significant improvements were found in the procedure for the administration of blood following the introduction of barcode patient identification, including an improvement from 11.8 to 100 percent in the correct verbal identification of patients (p </= 0.001). Similar significant improvements were found in matching verbally stated identification details with details on patient identification wristbands, in correct patient identification before the collection of blood samples, and in the proportion of correctly labeled samples. Staff found the barcode identification system easy to operate and preferred it to standard procedures.
Conclusions: A barcode patient identification system was found to simplify the clinical transfusion process and improve practice. These results provide support for further work on the development of such systems for transfusion and for other hospital procedures requiring patient identification.
Similar articles
-
End-to-end electronic control of the hospital transfusion process to increase the safety of blood transfusion: strengths and weaknesses.Transfusion. 2006 Mar;46(3):352-64. doi: 10.1111/j.1537-2995.2006.00729.x. Transfusion. 2006. PMID: 16533276
-
Use of an electronic barcode system for patient identification during blood transfusion: 3-year experience in a regional hospital.Hong Kong Med J. 2004 Jun;10(3):166-71. Hong Kong Med J. 2004. PMID: 15181220
-
Piloting the use of 2D barcode and patient safety-software in an Australian tertiary hospital setting.Vox Sang. 2013 Aug;105(2):159-66. doi: 10.1111/vox.12034. Epub 2013 Apr 19. Vox Sang. 2013. PMID: 23600799 Clinical Trial.
-
Barcode identification for transfusion safety.Curr Opin Hematol. 2004 Sep;11(5):334-8. doi: 10.1097/01.moh.0000142801.38087.e5. Curr Opin Hematol. 2004. PMID: 15666657 Review.
-
Transfusion practice and safety: current status and possibilities for improvement.Vox Sang. 2011 Jan;100(1):46-59. doi: 10.1111/j.1423-0410.2010.01366.x. Vox Sang. 2011. PMID: 21175655 Review.
Cited by
-
Blood transfusion.Arch Dis Child. 2004 Jan;89(1):4-7. Arch Dis Child. 2004. PMID: 14709489 Free PMC article. No abstract available.
-
Implementation challenges of electronic blood transfusion safety systems: Lessons from an international, multi-site comparative case study.Transfus Med. 2025 Feb;35(1):48-59. doi: 10.1111/tme.13095. Epub 2024 Sep 9. Transfus Med. 2025. PMID: 39252454 Free PMC article.
-
Effectiveness of barcoding for reducing patient specimen and laboratory testing identification errors: a Laboratory Medicine Best Practices systematic review and meta-analysis.Clin Biochem. 2012 Sep;45(13-14):988-98. doi: 10.1016/j.clinbiochem.2012.06.019. Epub 2012 Jun 28. Clin Biochem. 2012. PMID: 22750145 Free PMC article.
-
The feasibility of digital pen and paper technology for vital sign data capture in acute care settings.AMIA Annu Symp Proc. 2006;2006:229-33. AMIA Annu Symp Proc. 2006. PMID: 17238337 Free PMC article. Clinical Trial.
-
Patient safety with blood products administration using wireless and bar-code technology.AMIA Annu Symp Proc. 2005;2005:614-8. AMIA Annu Symp Proc. 2005. PMID: 16779113 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical