Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2003 Sep;49(9):1483-90.
doi: 10.1373/49.9.1483.

Comparison of diagnostic accuracies in outpatients and hospitalized patients of D-dimer testing for the evaluation of suspected pulmonary embolism

Affiliations
Comparative Study

Comparison of diagnostic accuracies in outpatients and hospitalized patients of D-dimer testing for the evaluation of suspected pulmonary embolism

John E Schrecengost et al. Clin Chem. 2003 Sep.

Abstract

Background: The ability of various D-dimer assays to exclude the diagnosis of thromboembolic diseases is controversial. We examined the diagnostic accuracy of two D-dimer methods in hospitalized patients and outpatients.

Methods: We studied consecutive patients for whom D-dimer testing was ordered for investigation of suspected pulmonary embolism. We measured D-dimer by an ELISA (VIDAS D-dimer) and an enhanced microlatex immunoassay method (Diagnostica Stago STA Liatest D-di). Patient diagnoses were based on imaging studies or, when these were not performed, on follow-up by review of medical records 3 months later.

Results: We examined 233 hospitalized patients and 234 outpatients with a mean age of 58 years (range, 1-92 years) and a female-to-male ratio of 1.4 to 1. Thromboembolism was present in 8% of outpatients and 12% of hospitalized patients. In outpatients, the negative predictive values were 98% [95% confidence interval (CI), 93-100%] and 99% (94-100%) for the microlatex and ELISA methods, respectively, at the recommended cutoffs. Areas under the ROC curves were similar for the two methods [0.77 (95% CI, 0.67-0.87) and 0.81 (0.73-0.89), respectively]. By contrast, in hospitalized patients, the confidence intervals for the areas under the ROC curves included 0.5 [0.60 (95% CI, 0.50-0.71) and 0.56 (0.44-0.67)].

Conclusions: For hospitalized patients, in contrast to outpatients, the diagnostic accuracy of D-dimer testing for pulmonary embolism is poor in a tertiary care setting, presumably reflecting thrombosis and comorbidities, other than pulmonary embolism, that increase the D-dimer concentrations in these patients. The patient population studied appears more important than assay method in studies of the diagnostic accuracy of D-dimer testing.

PubMed Disclaimer

Publication types

Substances