. 1992 Oct:456:71-83.
doi: 10.1113/jphysiol.1992.sp019327.

The ventilatory response to CO2 of the peripheral and central chemoreflex loop before and after sustained hypoxia in man

Affiliations

The ventilatory response to CO2 of the peripheral and central chemoreflex loop before and after sustained hypoxia in man

A Berkenbosch et al. J Physiol. 1992 Oct.

Abstract

1. The ventilatory response to sustained hypoxia is characterized by a fast increase due to the peripheral chemoreceptors followed by a slow decline. The mechanism of this decline is unknown. 2. To investigate the characteristics of the ventilatory response to sustained hypoxia ten healthy subjects were exposed to two consecutive periods of isocapnic hypoxia (arterial saturation 78%) separated by a 5 min exposure to isocapnic normoxia. 3. The acute hypoxic response to the second exposure to hypoxia (mean increase in ventilation +/- S.E.M., 7.2 +/- 0.8 l min-1) was significantly depressed (P = 0.04) compared to the first one (9.5 +/- 1.3 l min-1). 4. To investigate whether this depression was due to central or peripheral effects or both we measured, in the same ten subjects, the normoxic ventilatory response to CO2 before and after a period of 25 min of hypoxia using the technique of dynamic end-tidal forcing. 5. Each response was separated into a fast peripheral and slow central component characterized by a CO2 sensitivity, time constant, time delay and an off-set. 6. A total of thirty-six prehypoxic and thirty posthypoxic responses were analysed. The ventilatory CO2 sensitivities of the peripheral and central chemoreflex loops and the overall off-set (apnoeic threshold) after 25 min of hypoxia were somewhat larger than their prehypoxic values, but this effect was not significant. 7. We argue that the hypoxic ventilatory decline in man is due to a change in the off-set of the peripheral chemoreflex loop.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Chest. 1976 Jul;70(1 Suppl):124-8 - PubMed
    1. Respir Physiol. 1984 Aug;57(2):171-88 - PubMed
    1. J Appl Physiol (1985). 1991 Sep;71(3):1123-8 - PubMed
    1. J Appl Physiol (1985). 1991 Feb;70(2):590-3 - PubMed
    1. J Appl Physiol (1985). 1990 Mar;68(3):1107-13 - PubMed

LinkOut - more resources