Inflammatory potential of dust from schools and building related symptoms
- PMID: 12937201
- PMCID: PMC1740613
- DOI: 10.1136/oem.60.9.e5
Inflammatory potential of dust from schools and building related symptoms
Abstract
Aims: To test whether the inflammatory potential of dust samples might be used to differentiate schools with high and low prevalence of building related symptoms (BRS) among the occupants.
Methods: Ten schools with high prevalence of BRS and 10 schools with low prevalence were selected. Dust collected from floors, horizontal surfaces, and exhaust outlets was tested at five concentrations on the lung epithelial cell line A549. The potency of the dust (PF) to stimulate IL-8 secretion was calculated from the initial linear part of the dose-response curves. The organic fraction of the dust samples was determined by incineration.
Results: The schools with low prevalence of symptoms had a BRS% of 4.4-11.0 and the schools with high prevalence a BRS% of 19.6-31.9. The PF of floor dust and surface dust correlated, and the PF was associated with the organic content of the dust. The schools with low prevalence of symptoms had a significantly lower PF than the schools with high prevalence. Using the cut point value of 4.5 ng IL-8/mg floor dust, significantly more high prevalence schools were found above the cut point than below.
Conclusion: The PF of the floor dust samples correlated significantly with the prevalence of symptoms in the schools. The content of endotoxin and microorganisms did not seem to explain the inflammatory potential of the dust or BRS, and the substances in the dust causing the inflammatory potential are presently unknown.
Similar articles
-
Building-related symptoms are linked to the in vitro toxicity of indoor dust and airborne microbial propagules in schools: A cross-sectional study.Environ Res. 2017 Apr;154:234-239. doi: 10.1016/j.envres.2017.01.015. Epub 2017 Jan 17. Environ Res. 2017. PMID: 28107741
-
Molds in floor dust and building-related symptoms among adolescent school children: a problem for boys only?Indoor Air. 2005;15 Suppl 10:17-24. doi: 10.1111/j.1600-0668.2005.00356.x. Indoor Air. 2005. PMID: 15926940
-
Building-related symptoms and inflammatory potency of dust from office buildings.Indoor Air. 2007 Dec;17(6):458-67. doi: 10.1111/j.1600-0668.2007.00493.x. Indoor Air. 2007. PMID: 18045270
-
Endotoxin, ergosterol, muramic acid and fungal DNA in dust from schools in Johor Bahru, Malaysia--Associations with rhinitis and sick building syndrome (SBS) in junior high school students.Sci Total Environ. 2016 Mar 1;545-546:95-103. doi: 10.1016/j.scitotenv.2015.12.072. Epub 2015 Dec 31. Sci Total Environ. 2016. PMID: 26745297
-
Microbiology on indoor air '99--what is new and interesting? An overview of selected papers presented in Edinburgh, August, 1999.Indoor Air. 2000 Jun;10(2):74-80. doi: 10.1034/j.1600-0668.2000.010002074.x. Indoor Air. 2000. PMID: 11980105 Review.
Cited by
-
The Toxicity of Wiped Dust and Airborne Microbes in Individual Classrooms Increase the Risk of Teachers' Work-Related Symptoms: A Cross-Sectional Study.Pathogens. 2021 Oct 21;10(11):1360. doi: 10.3390/pathogens10111360. Pathogens. 2021. PMID: 34832514 Free PMC article.
-
Differential response of Mono Mac 6, BEAS-2B, and Jurkat cells to indoor dust.Environ Health Perspect. 2007 Sep;115(9):1325-32. doi: 10.1289/ehp.9874. Environ Health Perspect. 2007. PMID: 17805423 Free PMC article.
-
Dust weight and asthma prevalence in the National Survey of Lead and Allergens in Housing (NSLAH).Environ Health Perspect. 2007 Feb;115(2):215-20. doi: 10.1289/ehp.9412. Epub 2006 Nov 7. Environ Health Perspect. 2007. PMID: 17384767 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical