T 1 rho-relaxation mapping of human femoral-tibial cartilage in vivo
- PMID: 12938129
- DOI: 10.1002/jmri.10358
T 1 rho-relaxation mapping of human femoral-tibial cartilage in vivo
Abstract
Purpose: To demonstrate the in vivo feasibility of measuring spin-lattice relaxation time in the rotating frame (T(1rho)); and T(1rho)-dispersion in human femoral cartilage. Furthermore, we aimed to compute the baseline T(1rho)-relaxation times and spin-lock contrast (SLC) maps on healthy volunteers, and compare relaxation times and signal-to-noise ratio (SNR) with corresponding T(2)-weighted images.
Materials and methods: All MR imaging experiments were performed on a 1.5 T GE Signa scanner (GEMS, Milwaukee, WI) using a custom built 15-cm transmit-receive quadrature birdcage radio-frequency (RF) coil. The T(1rho)-prepared magnetization was imaged with a single-slice two-dimensional fast spin-echo (FSE) pulse sequence preencoded with a three-pulse cluster consisting of two hard 90 degrees pulses and a low power spin-lock pulse. T(1rho)-dispersion imaging was performed by varying the spin-lock frequency from 100 to 500 Hz in five steps in addition to varying the length of the spin-lock pulse.
Results: The average T(1rho)-relaxation times in the weight-bearing (WB) and nonweight-bearing (NWB) regions of the femoral condyle were 42.2 +/- 3.6 msec and 55.7 +/- 2.3 msec (mean +/- SD, N = 5, P < 0.0001), respectively. In the same regions, the corresponding T(2)-relaxation times were 31.8 +/- 1.5 msec and 37.6 +/- 3.6 msec (mean +/- SD, N = 5, P < 0.0099). T(1rho)-weighted images have approximately 20%-30% higher SNR than the corresponding T(2)-weighted images for similar echo time. The average SLC in the WB region of femoral cartilage was 30 +/-4.0%. Furthermore, SLC maps provide better contrast between fluid and articular surface of femoral-tibial joint than T(1rho)-maps. The T(1rho)-relaxation times varied from 32 msec to 42 msec ( approximately 31%) in the WB and 37 msec to 56 msec ( approximately 51%) in NWB regions of femoral condyle, respectively, in the frequency range 0-500 Hz (T(1rho)-dispersion).
Conclusion: The feasibility of performing in vivo T(1rho) relaxation mapping in femoral cartilage at 1.5T clinical scanner without exceeding Food and Drug Administration (FDA) limits on specific absorption rate (SAR) of RF energy was demonstrated.
Copyright 2003 Wiley-Liss, Inc.
Similar articles
-
3D-T1rho-relaxation mapping of articular cartilage: in vivo assessment of early degenerative changes in symptomatic osteoarthritic subjects.Acad Radiol. 2004 Jul;11(7):741-9. doi: 10.1016/j.acra.2004.03.051. Acad Radiol. 2004. PMID: 15217591
-
Proton spin-lock ratio imaging for quantitation of glycosaminoglycans in articular cartilage.J Magn Reson Imaging. 2003 Jan;17(1):114-21. doi: 10.1002/jmri.10228. J Magn Reson Imaging. 2003. PMID: 12500280
-
3D-T1rho quantitation of patellar cartilage at 3.0T.J Magn Reson Imaging. 2006 Dec;24(6):1357-63. doi: 10.1002/jmri.20733. J Magn Reson Imaging. 2006. PMID: 17058202
-
Magnetic resonance characterization of tissue engineered cartilage via changes in relaxation times, diffusion coefficient, and shear modulus.Crit Rev Biomed Eng. 2014;42(2):137-91. doi: 10.1615/critrevbiomedeng.2014011843. Crit Rev Biomed Eng. 2014. PMID: 25403876 Review.
-
T2 Relaxation Times at Cardiac MRI in Healthy Adults: A Systematic Review and Meta-Analysis.Radiology. 2020 Nov;297(2):344-351. doi: 10.1148/radiol.2020200989. Epub 2020 Aug 25. Radiology. 2020. PMID: 32840469 Free PMC article.
Cited by
-
Conventional and ultrashort time-to-echo magnetic resonance imaging of articular cartilage, meniscus, and intervertebral disk.Top Magn Reson Imaging. 2010 Oct;21(5):275-89. doi: 10.1097/RMR.0b013e31823ccebc. Top Magn Reson Imaging. 2010. PMID: 22129641 Free PMC article. Review.
-
Quantitative susceptibility and T1 mapping of knee articular cartilage at 3T.Osteoarthr Cartil Open. 2024 Aug 5;6(3):100509. doi: 10.1016/j.ocarto.2024.100509. eCollection 2024 Sep. Osteoarthr Cartil Open. 2024. PMID: 39224132 Free PMC article.
-
Combined off-resonance imaging and T2 relaxation in the rotating frame for positive contrast MR imaging of infection in a murine burn model.J Magn Reson Imaging. 2010 Nov;32(5):1172-83. doi: 10.1002/jmri.22349. J Magn Reson Imaging. 2010. PMID: 21031524 Free PMC article.
-
Three-dimensional spin-lock magnetic resonance imaging of the shoulder joint at 3 T: initial experience.Skeletal Radiol. 2007 Dec;36(12):1171-5. doi: 10.1007/s00256-007-0368-5. Epub 2007 Oct 3. Skeletal Radiol. 2007. PMID: 17912522
-
Cartilage dysfunction in ALS patients as side effect of motion loss: 3D mechano-electrochemical computational model.Biomed Res Int. 2014;2014:179070. doi: 10.1155/2014/179070. Epub 2014 Jun 3. Biomed Res Int. 2014. PMID: 24991537 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous