Measurement of retinal thickness in normal subjects with retinal thickness analyzer
- PMID: 12938527
- DOI: 10.1007/BF02886972
Measurement of retinal thickness in normal subjects with retinal thickness analyzer
Abstract
The retinal thickness at posterior pole of normal subjects was measured by using retinal thickness analyzer (RTA) to determine the values of retinal thickness and to establish map of retinal thickness in normal subjects. The retina of 6 mm x 6 mm in size (approximately 20 degrees, centered on the macula) at the posterior pole was scanned by using RTA to obtain images of 116 normal eyes of 77 cases of various age group. The images were processed by a computer to obtain the retinal thickness values and the thickness map of this location. The data were analyzed with SAS software package. The mean retinal thickness was 171.77 +/- 26.13 microns with no significant difference among the various age groups (P > 0.05). The thickness maps of the retina of 6 mm x 6 mm size at the posterior pole around the macula rendered a "U"-shaped pattern, extending from the disc to the superior and inferior of the fovea. The retina was found to be thin at temporal side of the fovea, with the thinnest area being at the macula central fovea. The U-shaped pattern of the retinal thickness maps was well in agreement with the topography of the ganglion cells and the retinal nerve fibers in human retina. The measurement of the retinal thickness by RTA reflected the changes in the layers of ganglion cells and the retinal nerve fiber. Each scanning session of RTA examination can yield multiple optical cross-section images of the retina and obtain retinal thickness maps of posterior pole of living eyes.
Similar articles
-
[Measurement of human retinal thickness at posterior pole with retinal thickness analyzer in normal and glaucomatous eyes].Zhonghua Yan Ke Za Zhi. 2000 Mar;36(2):124-8, 11. Zhonghua Yan Ke Za Zhi. 2000. PMID: 11853600 Chinese.
-
Noninvasive mapping of the normal retinal thickness at the posterior pole.Ophthalmology. 1999 Feb;106(2):269-73. doi: 10.1016/S0161-6420(99)90057-X. Ophthalmology. 1999. PMID: 9951475
-
[Evaluation of retinal thickness in the macula region in a population of healthy subjects by using the retinal thickness analyzer RTA].Klin Oczna. 2009;111(7-9):217-20. Klin Oczna. 2009. PMID: 19899577 Polish.
-
[A new approach for studying the retinal and choroidal circulation].Nippon Ganka Gakkai Zasshi. 2004 Dec;108(12):836-61; discussion 862. Nippon Ganka Gakkai Zasshi. 2004. PMID: 15656089 Review. Japanese.
-
[New examination methods for macular disorders--application of diagnosis and treatment].Nippon Ganka Gakkai Zasshi. 2000 Dec;104(12):899-942. Nippon Ganka Gakkai Zasshi. 2000. PMID: 11193944 Review. Japanese.
Cited by
-
Preliminary studies on the application of retinal thickness analyzer in the diagnosis of glaucoma.J Tongji Med Univ. 2000;20(3):257-60. doi: 10.1007/BF02887007. J Tongji Med Univ. 2000. PMID: 11215065
-
Use of macular thickness parameters for the diagnosis of primary open-angle glaucoma.Arch Med Sci. 2014 Feb 24;10(1):104-9. doi: 10.5114/aoms.2014.40736. Epub 2014 Feb 23. Arch Med Sci. 2014. PMID: 24701222 Free PMC article.