Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Sep 9;108(10):1214-20.
doi: 10.1161/01.CIR.0000087401.19332.B7. Epub 2003 Aug 25.

Differentiation of ischemic from nonischemic cardiomyopathy during dobutamine stress by left ventricular long-axis function: additional effect of left bundle-branch block

Affiliations

Differentiation of ischemic from nonischemic cardiomyopathy during dobutamine stress by left ventricular long-axis function: additional effect of left bundle-branch block

Alison M Duncan et al. Circulation. .

Abstract

Background: Resting regional wall-motion abnormalities do not reliably distinguish ischemic from nonischemic cardiomyopathy. Dobutamine stress echocardiography with use of the wall-motion score index (WMSI) identifies coronary artery disease (CAD) in dilated cardiomyopathy (DCM), but the technique is subjective and further complicated by left bundle-branch block (LBBB). Long-axis motion is sensitive to ischemia and can be assessed quantitatively. We aimed to compare long-axis function with WMSI for detecting CAD in DCM with or without LBBB.

Methods and results: Seventy-three patients with DCM, 48 with CAD (16 with LBBB), and 25 without CAD (10 with LBBB) were studied. Long-axis M-mode, pulsed-wave tissue Doppler echograms (lateral, septal, and posterior walls), and WMSI were assessed at rest and at peak dobutamine stress. Failure to increase systolic amplitude (total amplitude minus postejection shortening) by 2 mm or early diastolic velocity by 1.1 cm/s was the best discriminator for CAD (systolic amplitude, sensitivity 85%, specificity 86%; lengthening velocity, 71% and 94%, respectively; P=NS). Both had greater predictive accuracy than did WMSI (sensitivity 67%, specificity 76%; P<0.001). The predictive accuracy of changes in septal long-axis function was similar to those of average long-axis function (systolic amplitude cutoff=1.5 mm, lengthening velocity cutoff=1.5 cm/s). However in LBBB, systolic amplitude proved to be the only significant discriminator for CAD, with sensitivity and specificity reaching 94% and 100%, respectively (P<0.01 versus early diastolic lengthening velocity).

Conclusions: Quantified stress long-axis function identifies CAD in DCM with greater sensitivity and specificity than does standard WMSI, particularly in the presence of LBBB.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources