Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Sep;179(1):93-101.
doi: 10.1046/j.1365-201X.2003.01148.x.

Non-linear dependence of interstitial fluid pressure on joint cavity pressure and implications for interstitial resistance in rabbit knee

Affiliations

Non-linear dependence of interstitial fluid pressure on joint cavity pressure and implications for interstitial resistance in rabbit knee

D Scott et al. Acta Physiol Scand. 2003 Sep.

Abstract

Aims: Synovium retains lubricating fluid in the joint cavity. Synovial outflow resistance estimated as dPj/dQs (Pj, joint fluid pressure and Qs trans-synovial flow) is greater, however, than expected from interstitial glycosaminoglycan concentration. This study investigates whether subsynovial fluid pressure increases with intra-articular pressure, as this would reduce the estimated resistance estimate.

Methods: Interstitial fluid pressure (Pif) was measured as a function of distance from the joint cavity in knees of anaesthetized rabbits, using servo-null pressure-measuring micropipettes and using an external 'window'. Joint fluid pressure Pj was either endogenous (-2.4 +/- 0.4 cmH2O, mean +/- SEM) or held at approximately 4, 8 or 15.0 cmH2O by a continuous intra-articular saline infusion that matched the trans-synovial interstitial drainage rate.

Results: At endogenous Pj the peri-articular Pif was subatmospheric (-1.9 +/- 0.3 cmH2O, n = 19). At raised Pj the Pif values became positive. Gradient dPif /dx was approximately 20 times steeper across synovium than subsynovium. Pif close to the synovium-subsynovium border (Pif*) increased as a non-linear function of Pj to 1.4 +/- 0.2 cmH2O (n = 23) at Pj = 4.3 +/- 0.1 cmH2O : 2.3 +/- 0.2 cmH2O (n = 17) at Pj = 7.6 +/- 0.2 cmH2O: and 3.0 +/- 0.4 cmH2O (n = 26) at Pj = 15 +/- 0.2 cmH2O (P = 0.03, anova).

Conclusions: Synovial resistivity is approximately 20x subsynovial resistivity. The increase in Pif*with Pj means that true synovial resistance d(Pj-Pif*)/dQs is overestimated 1.5x by dPj/dQs. This narrows but does not eliminate the gap between analysed glycosaminoglycan concentration, 4 mg ml(-1), and the net interstitial biopolymer concentration of 11.5 mg ml(-1) needed to generate the resistance.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Substances

LinkOut - more resources