Protective equipment for health care facility decontamination personnel: regulations, risks, and recommendations
- PMID: 12944890
- DOI: 10.1016/s0196-0644(03)00447-5
Protective equipment for health care facility decontamination personnel: regulations, risks, and recommendations
Abstract
After recent terrorist attacks, new attention has been focused on health care facility decontamination practices. This article reviews core issues related to the selection of appropriate personal protective equipment for health care facility decontamination personnel, with an emphasis on respiratory protection. Existing federal regulations focus primarily on scene response and not on issues specific to health care facility decontamination practices. Review of existing databases, relevant published literature, and individual case reports reveal some provider health risks, especially when the exposure involves organophosphate agents. However, reported risks from secondary exposure to contaminated patients at health care facilities are low. These risks should be adequately addressed with Level C personal protective equipment, including air-purifying respirator technologies, unless the facility determines that specific local threats require increased levels of protection.
Comment in
-
Strip and shower: the duck and cover for the 21st century.Ann Emerg Med. 2003 Sep;42(3):391-4. doi: 10.1067/mem.2003.381. Ann Emerg Med. 2003. PMID: 12944892 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources