Development and evaluation of a three-dimensional hyperthermia applicator with Water-COated Antennas (WACOA)
- PMID: 12945971
- DOI: 10.1118/1.1589611
Development and evaluation of a three-dimensional hyperthermia applicator with Water-COated Antennas (WACOA)
Abstract
A novel twelve-channel three-dimensional (3-D) hyperthermia applicator has been developed and evaluated, which consists of twelve separate WAter COated Antenna (WACOA) modules. The modules are arranged in three transversal antenna rings (sub-arrays) and are placed into an acrylic applicator frame as cartridge-like elements in a staggered arrangement. The operating frequency is 100 MHz. For the design of the applicator, the finite-difference time-domain (FDTD) method was used. The applicator's dimensions allow its placement into the gantry of a magnetic resonance (MR) tomograph. The WACOA modules are designed as MR-compatible specially shaped metallic cylindrical dipole structures that are placed into hermetically closed water-filled cassettes. Due to the design of the dipole structures, only a conventional coaxial feed circuitry is needed, and no external impedance matching networks are necessary. Instead, fine on-line impedance matching is realized using adjustable tuning rods and matching rings, both elements being parts of the radiating antenna structure. Experimental and numerical evaluations demonstrate a good stability of impedance matching, a low inter-channel coupling of less than -20 dB, and a good ability of field pattern steering.
Similar articles
-
A clinical water-coated antenna applicator for MR-controlled deep-body hyperthermia: a comparison of calculated and measured 3-D temperature data sets.IEEE Trans Biomed Eng. 2005 Mar;52(3):505-19. doi: 10.1109/TBME.2004.843291. IEEE Trans Biomed Eng. 2005. PMID: 15759581
-
Experimental and numerical investigation of feed-point parameters in a 3-D hyperthermia applicator using different FDTD models of feed networks.IEEE Trans Biomed Eng. 2002 Nov;49(11):1348-59. doi: 10.1109/TBME.2002.804585. IEEE Trans Biomed Eng. 2002. PMID: 12450365
-
Antenna arrays in the SIGMA-eye applicator: interactions and transforming networks.Med Phys. 2001 Aug;28(8):1793-805. doi: 10.1118/1.1388220. Med Phys. 2001. PMID: 11548952
-
Computer-aided design of two-dimensional electric-type hyperthermia applicators using the finite-difference time-domain method.IEEE Trans Biomed Eng. 1991 Sep;38(9):861-70. doi: 10.1109/10.83606. IEEE Trans Biomed Eng. 1991. PMID: 1743734
-
A practical approach to thermography in a hyperthermia/magnetic resonance hybrid system: validation in a heterogeneous phantom.Int J Radiat Oncol Biol Phys. 2005 Jan 1;61(1):267-77. doi: 10.1016/j.ijrobp.2004.05.009. Int J Radiat Oncol Biol Phys. 2005. PMID: 15629620
Cited by
-
Fast PRF-based MR thermometry using double-echo EPI: in vivo comparison in a clinical hyperthermia setting.MAGMA. 2015 Aug;28(4):305-14. doi: 10.1007/s10334-014-0467-y. Epub 2014 Nov 8. MAGMA. 2015. PMID: 25381180
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous