Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2003 Sep;58(9):761-4.
doi: 10.1136/thorax.58.9.761.

Short and long term variability of the interrupter technique under field and standardised conditions in 3-6 year old children

Affiliations
Clinical Trial

Short and long term variability of the interrupter technique under field and standardised conditions in 3-6 year old children

R M J Beelen et al. Thorax. 2003 Sep.

Abstract

Background: The short and long term variability of the interrupter technique was assessed to determine whether interrupter resistance is a stable individual characteristic over time. The effect of field and standardised measurement conditions on the within-subject variability of the interrupter technique was also examined.

Methods: The interrupter technique was studied under field and standardised conditions in children aged 3-6 years. Under field conditions, five investigators performed the measurements using two different measurement devices in random sequence. Both short term (20-30 minutes) and long term variability (median 38 days) were assessed in 32 children. Under standardised conditions, a single investigator conducted all measurements using a single device; the repeated measurements were conducted at the same time of day in a familiar quiet classroom. Long term variability (median 11 days) was estimated in 15 children. Within-subject standard deviations were estimated by analysis of variance with adjustment for the effects of different investigators and measurement devices on within-subject variability under field conditions.

Results: Under field conditions within-subject standard deviations for short and long term variability were 0.10 kPa/l/s (adjusted 0.10 kPa/l/s) and 0.13 kPa/l/s (adjusted 0.14 kPa/l/s), respectively. Under standardised conditions the within-subject standard deviation for long term variability was 0.10 kPa/l/s.

Conclusions: Measurement of interrupter resistance under field conditions only slightly increased the within-subject variability compared with standardised conditions. The results indicate that interrupter resistance is a stable individual characteristic over a period of some weeks.

PubMed Disclaimer

Comment in

References

    1. Thorax. 1991 Jun;46(6):454-6 - PubMed
    1. Eur Respir J. 1993 Jul;6(7):996-1003 - PubMed
    1. Lancet. 1986 Feb 8;1(8476):307-10 - PubMed
    1. Thorax. 2001 Sep;56(9):691-5 - PubMed
    1. Eur Respir J. 2001 Jun;17(6):1244-9 - PubMed