Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2003 Jul;13(6):541-5.
doi: 10.1177/112067210301300606.

The effect of capsulorhexis size on development of posterior capsule opacification: small (4.5 to 5.0 mm) versus large (6.0 to 7.0 mm)

Affiliations
Clinical Trial

The effect of capsulorhexis size on development of posterior capsule opacification: small (4.5 to 5.0 mm) versus large (6.0 to 7.0 mm)

U Aykan et al. Eur J Ophthalmol. 2003 Jul.

Abstract

Purpose: The most common surgically related cause of reduced vision after extracapsular cataract extraction is posterior capsule opacification (PCO), which occurs in up to 50% of eyes following cataract extraction. This study examined whether small capsulorhexes of 4.5 to 5.0 mm, which lie completely on the 5.5 mm intraocular lens (IOL), and large capsulorhexes of 6.0 to 7.0 mm, which lie completely off the lens optic, are effective in preventing PCO development.

Methods: In this prospective study, 496 eyes of 367 patients underwent standardized phacoemulsification with capsulorhexis and capsular bag foldable acrylic IOL implantation. The patients were randomly assigned to receive either a small capsulorhexis of 4.5 to 5 mm to lie completely on the IOL optic or a large capsulorhexis of 6 to 7 mm to lie completely off the lens optic. Retroillumination photographs were taken at 6 months and then yearly.

Results: Throughout the follow-up, there was less PCO in the small capsulorhexis group than in the large capsulorhexis group. CONCLUSIONS.:Small capsulorhexes were associated with less wrinkling of the posterior capsule and less PCO than were large capsulorhexes. PCO after IOL implantation has a multifactored pathogenesis. Small (4.5 to 5.0 mm) capsulorhexis and capsular bag implantation of 5.5 mm acrylic IOL are likely to reduce the PCO incidence when compared with the 6.0 to 7.0 mm capsulorhexis. The significance of the IOL optic diameter in association with the capsulorhexis size should also be documented by further studies.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources