Practical issues in cardiac resynchronization therapy device implantation
- PMID: 12949443
Practical issues in cardiac resynchronization therapy device implantation
Abstract
Cardiac resynchronization utilizes left ventricular (LV) pacing through electrodes inserted through the coronary sinus (CS) into LV veins to stimulate the LV myocardium. Successful insertion of LV pacing leads requires an understanding of the anatomic changes associated with cardiac remodeling and a combination of standard pacing and cardiac catheterization and interventional techniques. CS catheterization and venography identify and access the target LV vein for insertion of the pacing lead. Obtaining an adequate lead position involves reaching appropriate capture thresholds, avoiding extra-cardiac stimulation, and stabilizing the lead to avoid dislodgement.
Similar articles
-
Surgical epicardial left ventricular lead versus coronary sinus lead placement in biventricular pacing.Eur J Cardiothorac Surg. 2005 Feb;27(2):235-42. doi: 10.1016/j.ejcts.2004.09.029. Eur J Cardiothorac Surg. 2005. PMID: 15691676
-
Cardiac resynchronization after left ventricular lead extraction: usefulness of angioplasty in coronary sinus stenosis.Pacing Clin Electrophysiol. 2008 Jul;31(7):908-11. doi: 10.1111/j.1540-8159.2008.01109.x. Pacing Clin Electrophysiol. 2008. PMID: 18684291
-
Lead positioning for cardiac resynchronization therapy: techniques and priorities.Europace. 2009 Nov;11 Suppl 5:v22-8. doi: 10.1093/europace/eup306. Europace. 2009. PMID: 19861387 Review.
-
Implantation of left ventricular leads using a telescopic catheter system.Pacing Clin Electrophysiol. 2006 Nov;29(11):1266-72. doi: 10.1111/j.1540-8159.2006.00529.x. Pacing Clin Electrophysiol. 2006. PMID: 17100682 Clinical Trial.
-
New tools for the effective delivery of cardiac resynchronization therapy.J Cardiovasc Electrophysiol. 2005 Sep;16 Suppl 1:S42-7. doi: 10.1111/j.1540-8167.2005.50186.x. J Cardiovasc Electrophysiol. 2005. PMID: 16138885 Review.
Cited by
-
Cardiac resynchronization therapy: strategies for device programming, troubleshooting and follow-up.J Interv Card Electrophysiol. 2005 Sep;13(3):209-22. doi: 10.1007/s10840-005-3247-9. J Interv Card Electrophysiol. 2005. PMID: 16177848 Review.
-
Novel steerable telescoping catheter system for implantation of left ventricular pacing leads.J Interv Card Electrophysiol. 2005 Jan;12(1):83-9. doi: 10.1007/s10840-005-5845-y. J Interv Card Electrophysiol. 2005. PMID: 15717156
MeSH terms
LinkOut - more resources
Medical