Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2003 Sep;14(9):940-8.
doi: 10.1046/j.1540-8167.2003.01554.x.

Analysis of implantable cardioverter defibrillator therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial

Affiliations
Clinical Trial

Analysis of implantable cardioverter defibrillator therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial

Richard C Klein et al. J Cardiovasc Electrophysiol. 2003 Sep.

Abstract

Introduction: The implantable cardioverter defibrillator (ICD) is commonly used to treat patients with documented sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Arrhythmia recurrence rates in these patients are high, but which patients will receive a therapy and the forms of arrhythmia recurrence (VT or VF) are poorly understood.

Methods and results: The therapy delivered by the ICD was examined in 449 patients randomized to ICD therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial. Events triggering ICD shocks or antitachycardia pacing (ATP) were reviewed for arrhythmia diagnosis, clinical symptoms, activity at the onset of the arrhythmia, and appropriateness and results of therapy. Both shock and ATP therapies were frequent by 2 years, with 68% of patients receiving some therapy or having an arrhythmic death. An appropriate shock was delivered in 53% of patients, and ATP was delivered in 68% of patients who had ATP activated. The first arrhythmia treated in follow-up was diagnosed as VT (63%), VF (13%), supraventricular tachycardia (18%), unknown arrhythmia (3%), or due to ICD malfunction or inappropriate sensing (3%). Acceleration of an arrhythmia by the ICD occurred in 8% of patients who received any therapy. No physical activity consistently preceded arrhythmias, nor did any single clinical factor predict the symptoms of the arrhythmia.

Conclusion: Delivery of ICD therapy in AVID patients was common, primarily due to VT. Inappropriate ICD therapy occurred frequently. Use of ICD therapy as a surrogate endpoint for death in clinical trials should be avoided.

PubMed Disclaimer

Publication types

MeSH terms

Substances

LinkOut - more resources