Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature
- PMID: 12955181
- DOI: 10.1007/s00134-003-1967-9
Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature
Abstract
Objective: Review of the accuracy and repeatability of Doppler cardiac output (CO) measurements in children.
Design: Publications in the scientific literature retrieved using a computerized Medline search from 1982-2002 and a manual review of article bibliographies. Studies comparing Doppler flow measurements with thermodilution, Fick, or dye dilution methods in the pediatric critical care setting were identified to assess the bias, precision, and intra- and interobserver repeatability of Doppler CO measurement. Where results were not suitable for comparison and the original measurements available, data were re-analyzed using appropriate statistical methods and presented in comparative tables.
Results: The precision of pediatric Doppler CO measurements compared to thermodilution, dye dilution, or Fick methods is around 30% and repeatability varies from less than 1% to 22%. Bias is generally less than 10% but varies considerably.
Conclusions: The bias, precision, and repeatability from study to study indicate that Doppler CO measurements are acceptably reproducible in children, with best results when used to track changes rather than absolute values, and using the transesophageal approach.
Similar articles
-
[Comparison of cardiac output measurement in critical patients using transesophageal Doppler or thermodilution: a preliminary report].Rev Med Chil. 2005 Jul;133(7):761-6. doi: 10.4067/s0034-98872005000700002. Epub 2005 Aug 26. Rev Med Chil. 2005. PMID: 16341381 Spanish.
-
Measurement of cardiac output after cardiac surgery by a new transesophageal Doppler device.J Cardiothorac Vasc Anesth. 2003 Apr;17(2):217-20. doi: 10.1053/jcan.2003.50. J Cardiothorac Vasc Anesth. 2003. PMID: 12698405
-
Simultaneous measurements of cardiac output by thermodilution, esophageal Doppler, and electrical impedance in anesthetized patients.J Cardiothorac Anesth. 1988 Oct;2(5):590-5. doi: 10.1016/0888-6296(88)90049-x. J Cardiothorac Anesth. 1988. PMID: 17171947
-
Measuring cardiac output: intermittent bolus thermodilution method.Crit Care Nurse. 2000 Apr;20(2):118-20, 122-4. Crit Care Nurse. 2000. PMID: 11873746 Review. No abstract available.
-
Non-invasive cardiac output monitoring.Intensive Crit Care Nurs. 2004 Apr;20(2):103-8. doi: 10.1016/j.iccn.2004.01.002. Intensive Crit Care Nurs. 2004. PMID: 15072778 Review.
Cited by
-
Estimation of cardiac output in a pharmacological trial using a simple method based on arterial blood pressure signal waveform: a comparison with pulmonary thermodilution and echocardiographic methods.Eur J Clin Pharmacol. 2006 Jun;62(6):401-7. doi: 10.1007/s00228-006-0115-1. Epub 2006 Mar 29. Eur J Clin Pharmacol. 2006. PMID: 16570186 Clinical Trial.
-
Evaluation of the estimated continuous cardiac output monitoring system in adults and children undergoing kidney transplant surgery: a pilot study.J Clin Monit Comput. 2014 Feb;28(1):95-9. doi: 10.1007/s10877-013-9501-2. Epub 2013 Aug 21. J Clin Monit Comput. 2014. PMID: 23963774
-
Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices.Intensive Care Med. 2009 Oct;35(10):1801-8. doi: 10.1007/s00134-009-1570-9. Epub 2009 Jul 11. Intensive Care Med. 2009. PMID: 19593546
-
Cardiovascular magnetic resonance of cardiac function and myocardial mass in preterm infants: a preliminary study of the impact of patent ductus arteriosus.J Cardiovasc Magn Reson. 2014 Jul 23;16(1):54. doi: 10.1186/s12968-014-0054-4. J Cardiovasc Magn Reson. 2014. PMID: 25160730 Free PMC article.
-
Assessing left ventricular systolic function in shock: evaluation of echocardiographic parameters in intensive care.Crit Care. 2011 Aug 16;15(4):R200. doi: 10.1186/cc10368. Crit Care. 2011. PMID: 21846331 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources