Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2003;30(3):229-32.

Delayed treatment of contained blunt traumatic aortic rupture: a case of rupture treated by endoprosthesis

Affiliations
Case Reports

Delayed treatment of contained blunt traumatic aortic rupture: a case of rupture treated by endoprosthesis

François Dagenais et al. Tex Heart Inst J. 2003.

Abstract

A 45-year-old man sustained an intracerebral frontal hematoma and a contained aortic isthmic rupture in a head-on automobile collision. Due to the intracerebral hemorrhage, open repair was contraindicated. Treatment with a stent graft was selected but delayed until the next morning, because the correct stent size was unavailable. Two hours before the time scheduled for surgery, the patient experienced oxygenation problems and became hypotensive. Chest radiography revealed a new, severe left hemothorax. Fortunately, the stent graft had just arrived from the manufacturer, and it was deployed to seal the ruptured aorta. Immediate angiography showed good stent-graft position without any endoleak as did a computed tomographic scan 2 days after the procedure. The patient was transferred to a rehabilitation unit to recover from his neurologic trauma. A 3-month follow-up computed tomographic scan showed the patient's condition to be unchanged.

PubMed Disclaimer

Figures

None
Fig. 1 Chest computed tomographic scan (A and B) shows the ruptured aortic isthmus.
None
Fig. 2 Aortogram confirms the ruptured aortic isthmus.
None
Fig. 3 Chest radiograph shows a new large left hemothorax.
None
Fig. 4 Postprocedure aortogram shows good endoprosthesis position and absence of endoleak.
None
Fig. 5 Computed tomographic scan (A and B) immediately after stent-graft placement confirms stent position and absence of any endoleak.

References

    1. Williams JS, Graff JA, Uku JM, Steinig JP. Aortic injury in vehicular trauma. Ann Thorac Surg 1994;57:726–30. - PubMed
    1. Merrill WH, Lee RB, Hammon JW Jr, Frist WH, Stewart JR, Bender HW Jr. Surgical treatment of acute traumatic tear of the thoracic aorta. Ann Surg 1988;207:699–706. - PMC - PubMed
    1. Duhaylongsod FG, Glower DD, Wolfe WG. Acute traumatic aortic aneurysm: the Duke experience from 1970 to 1990. J Vasc Surg 1992;15:331–43. - PubMed
    1. Maggisano R, Nathens A, Alexandrova NA, Cina C, Boulanger B, McKenzie R, Harrison AW. Traumatic rupture of the thoracic aorta: should one always operate immediately? Ann Vasc Surg 1995;9:44–52. - PubMed
    1. Parmley LF, Mattingly TW, Marian WC, Jahnke EJ. Nonpenetrating traumatic injury of the aorta. Circulation 1958;17:1086–100. - PubMed

Publication types