The use of a subfascial vicryl mesh buttress to aid in the closure of massive ventral hernias following damage-control laparotomy
- PMID: 12960857
- DOI: 10.1097/01.PRS.0000070175.10990.51
The use of a subfascial vicryl mesh buttress to aid in the closure of massive ventral hernias following damage-control laparotomy
Abstract
Damage control laparotomy for life-threatening abdominal conditions has gained wide acceptance in the management of exsanguinating trauma patients as well as septic patients with acute abdomen. Survivors considered too ill to undergo definitive abdominal wall closure are temporized, often with skin grafting on granulated viscera. These maneuvers compromise the integrity of the anterior abdominal wall and result in a subset of patients with loss of abdominal domain and massive, debilitating ventral hernias. A retrospective review was conducted of 21 such patients (16 men, five women) who underwent elective abdominal wall reconstruction at the Hospital of the University of Pennsylvania between November of 1998 and October of 2000. The purpose of this study was to report the authors' experience with these complex abdominal wall reconstructions. A double-layer, subfascial Vicryl mesh buttress was used in all repairs to aid in reestablishing abdominal wall integrity. The mean hernia size was 813 cm2 (range, 75 to 1836 cm2), and the average interval to definitive repair was 24.4 months (range, 3 weeks to 11 years). Mean follow-up was 13.5 months (range, 1 month to 40 months). Twenty patients (95 percent) had successful ventral hernia repair. Four patients with massive hernias (924 to 1836 cm2) required submuscular Marlex mesh implantation. Two patients (10 percent) developed abdominal compartment syndrome that required surgical decompression. One patient (5 percent) developed an incisional hernia at a prior colostomy site. Four patients (19 percent) had superficial skin dehiscence that healed secondarily with daily wound care. There were no mesh infections. In most cases, successful single-stage repair of large ventral hernias following damage control laparotomy can be achieved using a subfascial Vicryl mesh buttress in combination with other established reconstructive techniques. Massive defects exceeding 900 cm2 typically require permanent mesh implantation to achieve fascial closure and to minimize the risk of postoperative abdominal compartment syndrome and recurrent herniation. This technique represents an improved solution to a complicated problem and optimizes the aesthetic and functional outcome for these debilitated patients.
Similar articles
-
Damage control abdomen: single-stage reconstruction using a vicryl mesh buttress.Ann Plast Surg. 2013 Mar;70(3):324-30. doi: 10.1097/SAP.0b013e3182361af9. Ann Plast Surg. 2013. PMID: 22791067
-
Staged management of giant abdominal wall defects: acute and long-term results.Ann Surg. 2003 Sep;238(3):349-55; discussion 355-7. doi: 10.1097/01.sla.0000086544.42647.84. Ann Surg. 2003. PMID: 14501501 Free PMC article.
-
[Management of large abdominal wall hernias with foreign implant materials (Gore-Tex patch)].Zentralbl Chir. 1997;122(10):879-84. Zentralbl Chir. 1997. PMID: 9446450 German.
-
[Laparoscopic incisional hernia repair: our experience and review of the literature].Chir Ital. 2007 Sep-Oct;59(5):671-7. Chir Ital. 2007. PMID: 18019639 Review. Italian.
-
[New developments in abdominal wall closure].Chirurg. 2000 Jul;71(7):743-53. doi: 10.1007/s001040051132. Chirurg. 2000. PMID: 10986596 Review. German.
Cited by
-
The Association of Coloproctology of Great Britain and Ireland consensus guidelines in emergency colorectal surgery.Colorectal Dis. 2021 Feb;23(2):476-547. doi: 10.1111/codi.15503. Colorectal Dis. 2021. PMID: 33470518 Free PMC article.
-
Characterization of the Mechanical Strength, Resorption Properties, and Histologic Characteristics of a Fully Absorbable Material (Poly-4-hydroxybutyrate-PHASIX Mesh) in a Porcine Model of Hernia Repair.ISRN Surg. 2013 May 28;2013:238067. doi: 10.1155/2013/238067. Print 2013. ISRN Surg. 2013. PMID: 23781348 Free PMC article.
-
Absorbable Polyglactin vs. Non-Cross-linked Porcine Biological Mesh for the Surgical Treatment of Infected Incisional Hernia.J Gastrointest Surg. 2020 Feb;24(2):435-443. doi: 10.1007/s11605-018-04095-8. Epub 2019 Jan 22. J Gastrointest Surg. 2020. PMID: 30671806
-
Development of novel electrospun absorbable polycaprolactone (PCL) scaffolds for hernia repair applications.Surg Endosc. 2012 Oct;26(10):2717-28. doi: 10.1007/s00464-012-2258-8. Epub 2012 Apr 27. Surg Endosc. 2012. PMID: 22538673
-
Imaging findings of implanted absorbable mesh in patients with breast partial resection.Yonsei Med J. 2008 Feb 29;49(1):111-8. doi: 10.3349/ymj.2008.49.1.111. Yonsei Med J. 2008. PMID: 18306477 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources