Left ventricular mass index reduction early after an isolated aortic valve replacement with St. Jude Medical 19A-HP
- PMID: 12962413
- DOI: 10.1007/BF02719468
Left ventricular mass index reduction early after an isolated aortic valve replacement with St. Jude Medical 19A-HP
Abstract
Objectives: It has been reported that the left ventricular mass index (LVMI) for the hypertrophic myocardium is reduced at an early stage following surgery. In this study, those factors affecting the changes in early postoperative LVMI were investigated in cases in which a St. Jude Medical 19A-HP (19HP) mechanical heart valve was used.
Methods: We studied 16 consecutive patients with pure aortic stenosis undergoing isolated aortic valve replacement using a 19HP between January 1994 and July 2001. The patients were all female, aged 64 +/- 6 years, with a body surface area of 1.44 +/- 0.10 m2 and preoperative New York Heart Association (NYHA) classification of 2.2 +/- 0.5. All patients underwent transthoracic echocardiography at 4.2 +/- 3.3 days before and 16.3 +/- 10.2 days after operation, and cardiac catheterization within a mean period of one month before operation. The correlations between the decrease of LVMI at 16.3 +/- 10.2 days after operation and perioperative parameters were determined.
Results: There was significant LVMI regression postoperatively (15 +/- 12%, p = 0.01), and only a significant negative correlation between the decrease of LVMI and preoperative left ventricular pressure (LVp) [r = -0.74, p < 0.01]. There was no effective LVMI reduction in the high preoperative LVp group (> or = 210 mmHg).
Conclusion: It is expected that in the high LVp group, huge wall stress was being applied to the left ventricular muscle immediately before surgery and in the early period after surgery. Preoperative LVp is an important index for determining the surgical timing and safe perioperative management. We recommend early surgical treatment before LVp becomes more than 210 mmHg.
Similar articles
-
Hemodynamic function of the standard St. Jude bileaflet disc valve has no clinical impact 10 years after aortic valve replacement.Scand Cardiovasc J. 2005 Sep;39(4):237-43. doi: 10.1080/14017430510035880. Scand Cardiovasc J. 2005. PMID: 16118072
-
Application of Regent mechanical valve in patients with small aortic annulus: 3-year follow-up.J Cardiothorac Surg. 2012 Sep 21;7:88. doi: 10.1186/1749-8090-7-88. J Cardiothorac Surg. 2012. PMID: 22999490 Free PMC article.
-
Early and Mid-term Outcome of the St. Jude Medical Regent 19-mm Aortic Valve Mechanical Prosthesis. Functional and Haemodynamic Evaluation.Heart Lung Circ. 2018 Feb;27(2):235-247. doi: 10.1016/j.hlc.2017.02.017. Epub 2017 Mar 28. Heart Lung Circ. 2018. PMID: 28400190
-
Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement.JACC Cardiovasc Imaging. 2016 Aug;9(8):924-33. doi: 10.1016/j.jcmg.2015.10.026. Epub 2016 May 25. JACC Cardiovasc Imaging. 2016. PMID: 27236530 Review.
-
What is the best approach in a patient with a failed aortic bioprosthetic valve: transcatheter aortic valve replacement or redo aortic valve replacement?Interact Cardiovasc Thorac Surg. 2015 Jun;20(6):837-43. doi: 10.1093/icvts/ivv037. Epub 2015 Mar 8. Interact Cardiovasc Thorac Surg. 2015. PMID: 25754372 Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical
Research Materials
Miscellaneous