Icodextrin: a review of its use in peritoneal dialysis
- PMID: 12962523
- DOI: 10.2165/00003495-200363190-00011
Icodextrin: a review of its use in peritoneal dialysis
Abstract
Icodextrin (Extraneal) is a high molecular weight glucose polymer developed specifically for use as an alternative osmotic agent to dextrose during the once-daily long-dwell exchange in peritoneal dialysis (PD). Isosmotic 7.5% icodextrin solution induces transcapillary ultrafiltration (UF) by a mechanism resembling 'colloid' osmosis (unlike hyper-osmolar dextrose-based solutions, which induce UF by crystalline osmosis). In addition, absorption of icodextrin from the peritoneal cavity is relatively slow compared with that of dextrose; this results not only in UF of longer duration, but also a lower carbohydrate load compared with medium (2.5%) and strong (4.25%) dextrose exchanges. In randomised clinical trials of up to 2 years in duration, administration of icodextrin for the long (8- to 16-hour) overnight exchange in continuous ambulatory peritoneal dialysis (CAPD) or daytime exchange in automated peritoneal dialysis (APD) produced net UF which exceeded that with 1.5% and 2.5% dextrose solutions (thereby improving fluid balance), and was equivalent to that with 4.25% dextrose solution. Icodextrin also increased peritoneal clearances of creatinine and urea nitrogen compared with 2.5% dextrose solution. The increase in UF volume with icodextrin was enhanced in CAPD patients with high peritoneal membrane permeability (i.e. high and high-average transporters), maintained in the small number of patients followed-up for 2 years and sustained during episodes of peritonitis. Icodextrin reduced the percentage of patients with net negative UF in contrast to 1.5% and 2.5% dextrose and, in noncomparative studies, extended PD technique survival in patients who had failed dextrose-based dialysis. The use of icodextrin was also associated with some symptomatic improvements and health-related quality of life advantages, and no adverse effect on patient survival, compared with dextrose, although confirmation of these findings is ideally required in appropriately designed studies. The tolerability of icodextrin was generally similar to that of dextrose-based solutions in controlled clinical trials, although there was an approximate three-fold increase in the risk of new skin rash (5.5% vs 1.7%). However, reports of severe cutaneous hypersensitivity reactions remain rare; this possibility should not preclude the use of the polymer.
Conclusion: 7.5% icodextrin solution offers the first feasible alternative to conventional dextrose solutions for the once-daily long-dwell exchange in PD. It is effective, generally well tolerated and appears to be most useful in situations of reduced or inadequate UF with dextrose, including in high and high-average transporters, during episodes of peritonitis and patients who have failed dextrose-based dialysis.
Similar articles
-
Superiority of icodextrin compared with 4.25% dextrose for peritoneal ultrafiltration.J Am Soc Nephrol. 2005 Feb;16(2):546-54. doi: 10.1681/ASN.2004090793. Epub 2004 Dec 29. J Am Soc Nephrol. 2005. PMID: 15625070 Clinical Trial.
-
Assessment of the effectiveness, safety, and biocompatibility of icodextrin in automated peritoneal dialysis. The Dextrin in APD in Amsterdam (DIANA) Group.Perit Dial Int. 2000;20 Suppl 2:S106-13. Perit Dial Int. 2000. PMID: 10911654 Clinical Trial.
-
Peritoneal ultrafiltration and serum icodextrin concentration during dialysis with 7.5% icodextrin solution in Japanese patients.Perit Dial Int. 2003 Jul-Aug;23(4):356-61. Perit Dial Int. 2003. PMID: 12968843 Clinical Trial.
-
Icodextrin: an alternative peritoneal dialysis fluid.Expert Opin Drug Metab Toxicol. 2008 Nov;4(11):1455-64. doi: 10.1517/17425255.4.11.1455. Expert Opin Drug Metab Toxicol. 2008. PMID: 18950286 Review.
-
Icodextrin Versus Glucose Solutions for the Once-Daily Long Dwell in Peritoneal Dialysis: An Enriched Systematic Review and Meta-analysis of Randomized Controlled Trials.Am J Kidney Dis. 2020 Jun;75(6):830-846. doi: 10.1053/j.ajkd.2019.10.004. Epub 2020 Feb 4. Am J Kidney Dis. 2020. PMID: 32033860
Cited by
-
A peritoneal-based automated wearable artificial kidney.Clin Exp Nephrol. 2008 Jun;12(3):171-80. doi: 10.1007/s10157-008-0050-9. Epub 2008 Apr 3. Clin Exp Nephrol. 2008. PMID: 18386116 Review.
-
Five Things to Know About Volume Overload in Peritoneal Dialysis.Can J Kidney Health Dis. 2023 Jan 20;10:20543581221150590. doi: 10.1177/20543581221150590. eCollection 2023. Can J Kidney Health Dis. 2023. PMID: 36704235 Free PMC article.
-
Hypertension in Pediatric Dialysis Patients: Etiology, Evaluation, and Management.Curr Hypertens Rep. 2018 Jun 8;20(7):61. doi: 10.1007/s11906-018-0857-z. Curr Hypertens Rep. 2018. PMID: 29884913 Review.
-
Incidence and mortality of new-onset glucose disorders in peritoneal dialysis patients in China: a meta-analysis.BMC Nephrol. 2020 Apr 29;21(1):152. doi: 10.1186/s12882-020-01820-x. BMC Nephrol. 2020. PMID: 32349684 Free PMC article. Review.
-
Fluid overload as a major target in management of cardiorenal syndrome: Implications for the practice of peritoneal dialysis.World J Nephrol. 2017 Jul 6;6(4):168-175. doi: 10.5527/wjn.v6.i4.168. World J Nephrol. 2017. PMID: 28729965 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources