The effects of abutment taper, length and cement type on resistance to dislodgement of cement-retained, implant-supported restorations
- PMID: 12964683
- DOI: 10.1016/S1059-941X(03)00006-8
The effects of abutment taper, length and cement type on resistance to dislodgement of cement-retained, implant-supported restorations
Abstract
Purpose: The purpose of this study was to compare the effect of 20 degrees and 30 degrees of total occlusal convergence (TOC), the occlusocervical dimension, and the type of cement on the tensile resistance to dislodgement of cement-retained, implant-supported restorations.
Materials and methods: Cylindrical preparations with TOC angles of 20 degrees and 30 degrees and occlusocervical dimensions of 4 mm (S) and 8 mm (L) were made through a machining process. The cylinders had a shoulder finish line of 1.0 mm in depth. Eight impressions were made of each machined cylinder and poured in type IV dental stone, for a total of 32 dies. Die spacer was applied to each die. A master wax pattern was designed, and the 32 wax patterns were marginated, invested, and cast in type IV gold alloy (n = 8). The gold crowns were cemented with Fleck's cement (zinc phosphate cement), Temp-Bond (zinc oxide eugenol cement), Temp-Bond plus Vaseline (30% by weight), and IMProv temporary cement (acrylic/urethane cement) under a 10-kg load and placed in a humidor at 37 degrees C for 1 hour before testing. A uniaxial tensile force was applied to the crown using an Instron machine with a crosshead speed of 5 mm/min until cement failure occurred. Analysis of variance models were fit to determine the effect of TOC, occlusocervical dimension, and cement type of the restorations on the mean tensile strength.
Results: For each type of cement, the mean tensile strengths were significantly higher at 20 degrees of TOC and 8 mm of occlusocervical dimension compared with the other preparations. At this preparation, IMProv had the highest mean tensile resistance to dislodgement (47.7 +/- 8.4 kg), followed by Fleck's (38.2 +/- 8.8 kg), Temp-Bond (35.9 +/- 4.4 kg), and Temp-Bond plus Vaseline (8.2 +/- 2.2 kg). No statistically significant difference was observed between Temp-Bond and Fleck's zinc phosphate cement when 20 degrees of TOC and 8 mm of occlusocervical dimension was used. There was no statistical difference in the mean tensile resistance to dislodgement for Temp-Bond plus Vaseline with different preparation designs (p > 0.05) except when 20 degrees of TOC and 8 mm of occlusocervical dimension was used. The mean tensile strength was significantly different between Temp-Bond and Temp-Bond plus Vaseline for each of the 4 preparation designs (p < 0.05). Among the cements tested, IMProv exhibited higher values, which were statistically different (p < 0.05). Restorations with greater occlusocervical dimension and less TOC exhibited higher tensile resistance to dislodgement.
Conclusions: Preparations with 20 degrees of TOC and 8 mm of occlusocervical dimension had significantly higher mean retentive values for all of the cements tested. Significant differences in mean tensile strength were observed, with the highest tensile resistance seen with IMProv, followed by Fleck's cement, and the lowest tensile resistance seen with Temp-Bond plus Vaseline.
Similar articles
-
Influence of abutment height and surface roughness on in vitro retention of three luting agents.Int J Oral Maxillofac Implants. 2012 Jan-Feb;27(1):36-41. Int J Oral Maxillofac Implants. 2012. PMID: 22299076
-
Cement selection for cement-retained crown technique with dental implants.J Prosthodont. 2008 Feb;17(2):92-96. doi: 10.1111/j.1532-849X.2007.00262.x. Epub 2007 Oct 30. J Prosthodont. 2008. PMID: 17971122
-
The effect of thermal cycling and air abrasion on cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures.Int J Oral Maxillofac Implants. 2007 Jul-Aug;22(4):569-74. Int J Oral Maxillofac Implants. 2007. PMID: 17929517
-
Tensile strength of cementing agents on the CeraOne system of dental prosthesis on implants.Implant Dent. 2008 Dec;17(4):451-60. doi: 10.1097/ID.0b013e31818c4947. Implant Dent. 2008. PMID: 19077583 Review.
-
A clinically focused discussion of luting materials.Aust Dent J. 2011 Jun;56 Suppl 1:67-76. doi: 10.1111/j.1834-7819.2010.01297.x. Aust Dent J. 2011. PMID: 21564117 Review.
Cited by
-
Influence of Luting Materials on the Retention of Cemented Implant-Supported Crowns: An In Vitro Study.Materials (Basel). 2018 Sep 28;11(10):1853. doi: 10.3390/ma11101853. Materials (Basel). 2018. PMID: 30274184 Free PMC article.
-
Retention and Clinical Performance of Zirconia Crowns: A Comprehensive Review.Int J Dent. 2020 Oct 15;2020:8846534. doi: 10.1155/2020/8846534. eCollection 2020. Int J Dent. 2020. PMID: 33123199 Free PMC article. Review.
-
Rationale for the use of CAD/CAM technology in implant prosthodontics.Int J Dent. 2013;2013:768121. doi: 10.1155/2013/768121. Epub 2013 Apr 16. Int J Dent. 2013. PMID: 23690778 Free PMC article.
-
Evaluation of the effect of surface roughness and modification of implant abutment axial wall on the retention of zirconium oxide copings before and after thermocycling.J Clin Exp Dent. 2024 Apr 1;16(4):e399-e405. doi: 10.4317/jced.61175. eCollection 2024 Apr. J Clin Exp Dent. 2024. PMID: 38725819 Free PMC article.
-
Retentiveness of implant-supported metal copings using different luting agents.Dent Res J (Isfahan). 2012 Jan;9(1):13-8. doi: 10.4103/1735-3327.92921. Dent Res J (Isfahan). 2012. PMID: 22363357 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous