A europium chelate for quantitative point-of-care immunoassays using direct surface measurement
- PMID: 12964769
- DOI: 10.1021/ac0340051
A europium chelate for quantitative point-of-care immunoassays using direct surface measurement
Abstract
New labels and assay techniques are needed to improve the sensitivity and quantitativeness of point-of-care immunotesting while sustaining the rapidity and ease of use of the assays. We synthesized a novel, intrinsically fluorescent nonadentate europium chelate with two chromophores and hydrophilic alpha-galactose side groups. The chelate is highly fluorescent, soluble in water, and provides effective shielding of Eu from water. The performance of the nonadentate chelate was compared with a heptadentate chelate in a dry reagent immunoassay for human chorionic gonadotropin (hCG). After 15-min incubation and washing, time-resolved fluorescence was measured directly from a wet or dried well surface. Contrary to the heptadentate label, the effect of aqueous quenching on the nonadentate label was found to be insignificant, with calculated analytical detection limits (background + 3 SD) of 0.9 and 0.7 IU/L hCG for wet and dry measurements, respectively, and a linear range up to 5000 IU/L. The CVs for the new label were <8% at the cutoff of 25 IU/L and above in both whole blood and plasma. The novel nonadentate label facilitates short turnaround times and simple instrumentation due to the absence of all signal development steps, at the same time retaining an excellent immunoassay performance.
Similar articles
-
Quantitative, wide-range, 5-minute point-of-care immunoassay for total human chorionic gonadotropin in whole blood.Clin Chem. 2004 Jun;50(6):1026-35. doi: 10.1373/clinchem.2004.031922. Epub 2004 Apr 8. Clin Chem. 2004. PMID: 15073089
-
One-step all-in-one dry reagent immunoassays with fluorescent europium chelate label and time-resolved fluorometry.Clin Chem. 1996 Aug;42(8 Pt 1):1196-201. Clin Chem. 1996. PMID: 8697576
-
Lateral flow immunoassay using europium chelate-loaded silica nanoparticles as labels.Clin Chem. 2009 Jan;55(1):179-82. doi: 10.1373/clinchem.2008.114561. Epub 2008 Oct 30. Clin Chem. 2009. PMID: 18974359
-
Europium chelate labels in time-resolved fluorescence immunoassays and DNA hybridization assays.Anal Chem. 1990 Nov 15;62(22):1149A-1157A. doi: 10.1021/ac00221a001. Anal Chem. 1990. PMID: 2270861 Review. No abstract available.
-
Rare earth cryptates and homogeneous fluoroimmunoassays with human sera.Clin Chem. 1993 Sep;39(9):1953-9. Clin Chem. 1993. PMID: 8375081 Review.
Cited by
-
Plastic versus glass support for an immunoassay on metal-coated surfaces in optically dense samples utilizing directional surface plasmon-coupled emission.J Fluoresc. 2005 Nov;15(6):865-71. doi: 10.1007/s10895-005-0015-2. J Fluoresc. 2005. PMID: 16328701 Free PMC article.
-
Design of Novel, Water Soluble and Highly Luminescent Europium Labels with Potential to Enhance Immunoassay Sensitivities.Molecules. 2017 Oct 24;22(10):1807. doi: 10.3390/molecules22101807. Molecules. 2017. PMID: 29064444 Free PMC article.
-
Photochemical characterization of up-converting inorganic lanthanide phosphors as potential labels.J Fluoresc. 2005 Jul;15(4):513-28. doi: 10.1007/s10895-005-2825-7. J Fluoresc. 2005. PMID: 16167210
-
Escherichia coli-expressed near full length HIV-1 envelope glycoprotein is a highly sensitive and specific diagnostic antigen.BMC Infect Dis. 2012 Nov 27;12:325. doi: 10.1186/1471-2334-12-325. BMC Infect Dis. 2012. PMID: 23186021 Free PMC article.
-
Evaluation of a new automated homogeneous PCR assay, GenomEra C. difficile, for rapid detection of Toxigenic Clostridium difficile in fecal specimens.J Clin Microbiol. 2013 Sep;51(9):2908-12. doi: 10.1128/JCM.01083-13. Epub 2013 Jun 26. J Clin Microbiol. 2013. PMID: 23804386 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources