A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models
- PMID: 12974580
- DOI: 10.1088/0031-9155/48/16/306
A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models
Abstract
The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and voxelized patient data. To accomplish this we have modified a general purpose Monte Carlo transport code (MCNP4B) to simulate the CT x-ray source and movement, and then to calculate absorbed radiation dose in desired objects. The movement of the source in either axial or spiral modes was modelled explicitly while the CT system components were modelled using published information about x-ray spectra as well as information provided by the manufacturer. Simulations were performed for single axial scans using the head and body computed tomography dose index (CTDI) polymethylmethacrylate phantoms at both central and peripheral positions for all available beam energies and slice thicknesses. For comparison, corresponding physical measurements of CTDI in phantom were made with an ion chamber. To obtain absolute dose values, simulations and measurements were performed in air at the scanner isocentre for each beam energy. To extend the verification, the CT scanner model was applied to the MIRD V model and compared with published results using similar technical factors. After verification of the model, the generalized source was simulated and applied to voxelized models of patient anatomy. The simulated and measured absolute dose data in phantom agreed to within 2% for the head phantom and within 4% for the body phantom at 120 and 140 kVp; this extends to 8% for the head and 9% for the body phantom across all available beam energies and positions. For the head phantom, the simulated and measured absolute dose data agree to within 2% across all slice thicknesses at 120 kVp. Our results in the MIRD phantom agree within 11% of all the different organ dose values published by the UK's ImPACT group for a scan using an equivalent scanner, kVp, collimation, pitch and mAs. The CT source model was shown to calculate both a relative and absolute radiation dose distribution throughout the entire volume in a patient-specific matrix geometry. Results of initial testing are promising and application to patient models was shown to be feasible.
Similar articles
-
A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.Phys Med Biol. 2005 Sep 7;50(17):3989-4004. doi: 10.1088/0031-9155/50/17/005. Epub 2005 Aug 11. Phys Med Biol. 2005. PMID: 16177525
-
On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations.Med Phys. 2008 May;35(5):2018-28. doi: 10.1118/1.2896075. Med Phys. 2008. PMID: 18561678
-
Organ and effective doses in newborn patients during helical multislice computed tomography examination.Phys Med Biol. 2006 Oct 21;51(20):5151-66. doi: 10.1088/0031-9155/51/20/005. Epub 2006 Sep 22. Phys Med Biol. 2006. PMID: 17019030
-
USE OF ANTHROPOMORPHIC HETEROGENEOUS PHYSICAL PHANTOMS FOR VALIDATION OF COMPUTATIONAL DOSIMETRY OF MEDICAL PERSONNEL AND PATIENTS.Probl Radiac Med Radiobiol. 2020 Dec;25:148-176. doi: 10.33145/2304-8336-2020-25-148-176. Probl Radiac Med Radiobiol. 2020. PMID: 33361833 Review. English, Ukrainian.
-
CT Dosimetry: What Has Been Achieved and What Remains to Be Done.Invest Radiol. 2021 Jan;56(1):62-68. doi: 10.1097/RLI.0000000000000727. Invest Radiol. 2021. PMID: 32932380 Review.
Cited by
-
Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes.Radiol Phys Technol. 2016 Jan;9(1):37-43. doi: 10.1007/s12194-015-0331-4. Epub 2015 Jul 25. Radiol Phys Technol. 2016. PMID: 26205316
-
Attenuation-based size metric for estimating organ dose to patients undergoing tube current modulated CT exams.Med Phys. 2015 Feb;42(2):958-68. doi: 10.1118/1.4906132. Med Phys. 2015. PMID: 25652508 Free PMC article.
-
Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry.Med Phys. 2015 Feb;42(2):1080-6. doi: 10.1118/1.4906178. Med Phys. 2015. PMID: 25652520 Free PMC article.
-
Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis.Pediatr Radiol. 2015 Nov;45(12):1771-80. doi: 10.1007/s00247-015-3400-2. Epub 2015 Jul 4. Pediatr Radiol. 2015. PMID: 26142256 Free PMC article.
-
Patient-specific radiation dose and cancer risk estimation in CT: part I. development and validation of a Monte Carlo program.Med Phys. 2011 Jan;38(1):397-407. doi: 10.1118/1.3515839. Med Phys. 2011. PMID: 21361208 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources