Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1992 Dec;85(12):1781-8.

[Holter monitoring of ventricular arrhythmia during the 24 first hours of myocardial infarction treated with intravenous thrombolysis]

[Article in French]
Affiliations
  • PMID: 1306619

[Holter monitoring of ventricular arrhythmia during the 24 first hours of myocardial infarction treated with intravenous thrombolysis]

[Article in French]
V Gressin et al. Arch Mal Coeur Vaiss. 1992 Dec.

Abstract

The aim of this study was to assess ventricular arrhythmias after intravenous thrombolysis for acute myocardial infarction and to determine their relationship with coronary artery patency. A 24 hour Holter recording was started 3.1 +/- 0.2 hours after the onset of pain in 40 patients (age 54 +/- 1.6 years, 42.5% anterior infarcts) treated by streptokinase (42.5%) or tissue plasminogen activator (57.5%) within 3.3 +/- 0.2 hours of the beginning of symptoms. The arrhythmias were analysed on a Marquette 8000 computer. Coronary angiography was systematic and was performed 26.7 +/- 2.5 hours (within 4 hours in 60% of patients) after the onset of pain to define coronary artery patency (TIMI 2 and 3: 72.5%) or occlusion (TIMI 0 or 1: 27.5%). Ventricular arrhythmias were common and generally well tolerated (one defibrillation for ventricular fibrillation). Accelerated idioventricular rhythms and ventricular tachycardias were equally prevalent in patients with patent arteries (90% and 83%) as with occluded arteries (82% and 73%). The prevalence of sustained ventricular tachycardias (> 15 complexes) and of early accelerated idioventricular rhythms (< or = 6 hours) was significantly higher in patients with patent coronary arteries: 38% versus 0% (p < 0.05) and 76% versus 18% (p < 0.01). These arrhythmias may be considered to be non-invasive markers of early coronary reperfusion, with a sensitivity of 38 and 76% and a specificity of 100 and 82%. Coronary patency was associated with higher numbers of ventricular extrasystoles, ventricular tachycardias and accelerated idioventricular rhythms by a factor of 14, 13 and 32 respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources