[Ischemic myocardial injury evaluated using positron emission tomography in children with coronary artery disease: comparison with thallium-201 SPECT]
- PMID: 1307567
[Ischemic myocardial injury evaluated using positron emission tomography in children with coronary artery disease: comparison with thallium-201 SPECT]
Abstract
Regional myocardial perfusion and glucose metabolism were evaluated by positron emission tomography (PET) in children with coronary artery disease. Also, PET findings were compared with those of thallium-201 myocardial single photon computed tomography (SPECT). The study patients consisted of 11 children ranging in age from 3 to 14 years. Ten patients had significantly stenotic coronary arterial lesions due to Kawasaki disease, and one patient had a left coronary artery with an anomalous origin from the pulmonary artery. Evaluation was made before and after surgical revascularization in 3 patients. Regional myocardial perfusion was assessed at rest using 13N-ammonia, and regional myocardial glucose metabolism was assessed at rest under fasting conditions using 18F-fluorodeoxyglucose (18FDG). SPECT was performed after dipyridamole infusion. Initial and delayed images were obtained 7 min and 3 hrs after dipyridamole infusion, respectively. Left ventricular myocardial images were categorized as the septal, anterior, lateral, apical, and inferior segments, and evaluation was made for each segment. A total of 70 myocardial segments in 11 patients were classified into 4 groups according to the PET findings: 1) segments with normal perfusion and without enhanced 18FDG uptake (normal segments; n = 55), 2) normal perfusion with enhanced 18FDG uptake (metabolically abnormal segments; n = 3), 3) hypoperfusion with enhanced 18FDG uptake (ischemic but viable segments; n = 9), and 4) hypoperfusion without enhanced 18FDG uptake (non-viable segments; n = 3). On SPECT, the numbers of myocardial segments showing no perfusion defects, complete redistribution, incomplete redistribution, and persistent perfusion defects were 38, 12, 14, and 6, respectively. Comparisons were made between PET findings and SPECT findings.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Identification of viable myocardium in patients with chronic coronary artery disease and left ventricular dysfunction. Comparison of thallium scintigraphy with reinjection and PET imaging with 18F-fluorodeoxyglucose.Circulation. 1991 Jan;83(1):26-37. doi: 10.1161/01.cir.83.1.26. Circulation. 1991. PMID: 1984883 Clinical Trial.
-
[18F]fluorodeoxyglucose single photon emission computed tomography: can it replace PET and thallium SPECT for the assessment of myocardial viability?Circulation. 1998 Mar 10;97(9):843-50. doi: 10.1161/01.cir.97.9.843. Circulation. 1998. PMID: 9521332
-
Evaluation of regional myocardial perfusion in patients with severe left ventricular dysfunction: comparison of 13N-ammonia PET and 99mTc sestamibi SPECT.J Nucl Cardiol. 1998 Jan-Feb;5(1):4-13. doi: 10.1016/s1071-3581(98)80004-4. J Nucl Cardiol. 1998. PMID: 9504867 Clinical Trial.
-
[Thallium scintigraphy for determining myocardial vitality. Evaluation of the "stunned and hibernating myocardium"].Herz. 1994 Feb;19(1):7-18. Herz. 1994. PMID: 8150416 Review. German.
-
Comparison of thallium scintigraphy and positron emission tomography.Angiology. 1997 Oct;48(10):843-53. doi: 10.1177/000331979704801001. Angiology. 1997. PMID: 9342963 Review.
Cited by
-
Positron emission tomography in paediatric cardiology.Arch Dis Child. 1998 Dec;79(6):520-2. doi: 10.1136/adc.79.6.520. Arch Dis Child. 1998. PMID: 10211000 Free PMC article. Review. No abstract available.
-
Role of myocardial perfusion single photon emission computed tomography in pediatric cardiology practice.Ann Pediatr Cardiol. 2009 Jul;2(2):127-39. doi: 10.4103/0974-2069.58314. Ann Pediatr Cardiol. 2009. PMID: 20808625 Free PMC article.