Detection of colorectal carcinomas by intraoperative RIS in addition to preoperative RIS: surgical and immunohistochemical findings
- PMID: 1314182
- DOI: 10.1007/BF00184124
Detection of colorectal carcinomas by intraoperative RIS in addition to preoperative RIS: surgical and immunohistochemical findings
Abstract
The immunoscintigraphic detection of tumour foci less than 1 cm in diameter fails even with single photon emission tomography (SPET) owing to low contrast against background activity. In an attempt to improve detection of macroscopically invisible tumour spread, intraoperative scintimetry (IOSM) with a hand-held gamma-probe was performed in addition to SPET 24-30 and 41-48 h after injection of the technetium-99m carcinoembryonic antigen (CEA MoA) on 12 patients with colorectal carcinoma and 3 patients with different neoplastic and inflammatory diseases. Tumour specimens were measured in vitro in a gamma well counter. For comparison, the presence and amount of CEA in the tumour cells were evaluated immunohistochemically. After modification, the gamma-probe originally designed for iodine-131 was 20 times more sensitive; activities of 99mTc located close to the collimator hole were measured with absolute sensitivity of 100 cps = 2.5 kBq 99mTc. The unfavourably high background activity affected both the in vitro and in vivo analysis: SPET results had been considered positive in 8 of 15 cases. In vitro tumour/non-tumour (t/nt) ratios greater than 2.0 were found in 4 cases. In vivo IOSM resulted in t/nt ratios greater than 2.0 in only 3 patients. In most cases, there was no coincidence of elevated t/nt ratios from the different methods. A correlation was derived between positive immunoscintimetric in vitro findings and immunohistochemically proven interstitial localization of CEA in tumor cells. In conclusion, the measurement technique of IOSM seems adequate, but clinical success will depend on a more specific enrichment of MoA in tumour tissue.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Preoperative scintigraphy and operative probe scintimetry of colorectal carcinoma using technetium-99m-88BV59.J Nucl Med. 1995 May;36(5):738-45. J Nucl Med. 1995. PMID: 7738642
-
[The clinical relevance of anti-CEA immunoscintigraphy with the 99mTc-labelled monoclonal antibody BW 431/26. A critical assessment after 119 studies].Rofo. 1992 Jul;157(1):3-10. doi: 10.1055/s-2008-1032956. Rofo. 1992. PMID: 1638001 German.
-
Technetium 99m-labeled IMMU-4, a monoclonal antibody against carcinoembryonic antigen, for imaging of occult recurrent colorectal cancer in patients with rising serum carcinoembryonic antigen levels.J Clin Oncol. 1994 Mar;12(3):489-95. doi: 10.1200/JCO.1994.12.3.489. J Clin Oncol. 1994. PMID: 8120546
-
Operative probe scintimetry with indium and technetium for colorectal cancer.J Surg Oncol. 2007 Sep 15;96(4):290-6. doi: 10.1002/jso.20870. J Surg Oncol. 2007. PMID: 17879338 Review.
-
[Radioimmunoscintigraphy of colorectal tumors: state of the art (2)].Aktuelle Radiol. 1992 Sep;2(5):262-70. Aktuelle Radiol. 1992. PMID: 1420384 Review. German.
Cited by
-
Peroperative nuclear medicine.Eur J Nucl Med. 1993 Jul;20(7):573-5. doi: 10.1007/BF00176549. Eur J Nucl Med. 1993. PMID: 8370377 No abstract available.
-
Evaluation of two intraoperative gamma detectors for assessment of 177Lu activity concentration in vivo.EJNMMI Phys. 2017 Dec;4(1):3. doi: 10.1186/s40658-016-0168-x. Epub 2017 Jan 9. EJNMMI Phys. 2017. PMID: 28070731 Free PMC article.
-
Didactic review of 175 radionuclide-guided excisions of osteoid osteomas.Eur J Nucl Med. 1996 Aug;23(8):1003-11. doi: 10.1007/BF01084380. Eur J Nucl Med. 1996. PMID: 8753695
References
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources
Medical
Research Materials