Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1992;19(2):102-9.
doi: 10.1007/BF00184124.

Detection of colorectal carcinomas by intraoperative RIS in addition to preoperative RIS: surgical and immunohistochemical findings

Affiliations

Detection of colorectal carcinomas by intraoperative RIS in addition to preoperative RIS: surgical and immunohistochemical findings

M Reuter et al. Eur J Nucl Med. 1992.

Abstract

The immunoscintigraphic detection of tumour foci less than 1 cm in diameter fails even with single photon emission tomography (SPET) owing to low contrast against background activity. In an attempt to improve detection of macroscopically invisible tumour spread, intraoperative scintimetry (IOSM) with a hand-held gamma-probe was performed in addition to SPET 24-30 and 41-48 h after injection of the technetium-99m carcinoembryonic antigen (CEA MoA) on 12 patients with colorectal carcinoma and 3 patients with different neoplastic and inflammatory diseases. Tumour specimens were measured in vitro in a gamma well counter. For comparison, the presence and amount of CEA in the tumour cells were evaluated immunohistochemically. After modification, the gamma-probe originally designed for iodine-131 was 20 times more sensitive; activities of 99mTc located close to the collimator hole were measured with absolute sensitivity of 100 cps = 2.5 kBq 99mTc. The unfavourably high background activity affected both the in vitro and in vivo analysis: SPET results had been considered positive in 8 of 15 cases. In vitro tumour/non-tumour (t/nt) ratios greater than 2.0 were found in 4 cases. In vivo IOSM resulted in t/nt ratios greater than 2.0 in only 3 patients. In most cases, there was no coincidence of elevated t/nt ratios from the different methods. A correlation was derived between positive immunoscintimetric in vitro findings and immunohistochemically proven interstitial localization of CEA in tumor cells. In conclusion, the measurement technique of IOSM seems adequate, but clinical success will depend on a more specific enrichment of MoA in tumour tissue.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Similar articles

Cited by

References

    1. Eur J Nucl Med. 1988;14 (11):523-8 - PubMed
    1. AJR Am J Roentgenol. 1988 Oct;151(4):697-703 - PubMed
    1. Radiology. 1988 Mar;166(3):747-52 - PubMed
    1. Onkologie. 1989 Aug;12 Suppl 1:13-8 - PubMed
    1. Int J Cancer. 1988 Sep 15;42(3):352-8 - PubMed

Substances