Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1992 Jun;66(6):3784-93.
doi: 10.1128/JVI.66.6.3784-3793.1992.

Determination of the poliovirus RNA polymerase error frequency at eight sites in the viral genome

Affiliations

Determination of the poliovirus RNA polymerase error frequency at eight sites in the viral genome

C D Ward et al. J Virol. 1992 Jun.

Abstract

The poliovirus RNA polymerase error frequency was measured in vivo at eight sites in the poliovirus genome. The frequency at which specific G residues in poliovirion RNA changed to another base during one round of viral RNA replication was determined. Poliovirion RNA uniformly labeled with 32Pi was hybridized to a synthetic DNA oligonucleotide that was complementary to a sequence in the viral genome that contained a single internal G residue. The nonhybridized viral RNA was digested with RNase T1, and the protected RNA oligonucleotide was purified by gel electrophoresis. The base substitution frequency at the internal G residue was measured by finding the fraction of this RNA oligonucleotide that was resistant to RNase T1 digestion. A mean value of 2.0 x 10(-3) +/- 1.2 x 10(-3) was obtained at two sites. A modification of the above procedure involved the use of 5'-end-labeled RNA oligonucleotides. The mean value of the error frequency determined at eight sites in the viral genome by using this technique was 4.1 x 10(-3) +/- 0.6 x 10(-3). Sequencing two of the RNase T1-resistant RNA oligonucleotides confirmed that the internal G was changed to a C, A, or U residue in most of these oligonucleotides. Thus, our results indicated that the polymerase had a high error frequency in vivo and that there was no significant variation in the values determined at the specific sites examined in this study.

PubMed Disclaimer

References

    1. J Virol. 1990 Aug;64(8):3960-2 - PubMed
    1. J Gen Virol. 1981 Oct;56(Pt 2):337-47 - PubMed
    1. J Virol. 1988 May;62(5):1781-94 - PubMed
    1. J Virol. 1989 May;63(5):2072-80 - PubMed
    1. J Virol. 1988 Feb;62(2):558-62 - PubMed

Publication types

LinkOut - more resources