Determination of a cyclic heptapeptide, a novel fibrinogen receptor antagonist, in human plasma by high-performance liquid chromatography with automated pre-column derivatization, column switching and fluorescence detection
- PMID: 1328269
- DOI: 10.1016/0378-4347(92)80221-b
Determination of a cyclic heptapeptide, a novel fibrinogen receptor antagonist, in human plasma by high-performance liquid chromatography with automated pre-column derivatization, column switching and fluorescence detection
Abstract
A sensitive high-performance liquid chromatographic (HPLC) assay for the determination of the cyclic heptapeptide Ac-Cs-Asn-Dtc-Amf-Gly-Asp-Cys-OH (Dtc = beta,beta-dimethylthioproline, Amf = p-aminomethylphenylalanine) in human plasma has been developed. The key steps in the assay include: solid-phase extraction of the drug from plasma, chemical derivatization of the primary amino group with naphthalene-2,3-dicarboxyaldehyde in the presence of N-acetyl-D-penicillamine as a nucleophile to form a fluorescent benzo[f]isoindole derivative, and HPLC with column switching to provide the necessary chromatographic separation of the derivative from endogenous plasma components. The assay has been validated in the concentration range 1-10 ng/ml of plasma.
Similar articles
-
Determination of 4-amino-1-hydroxybutane-1,1-bisphosphonic acid in urine by automated pre-column derivatization with 2,3-naphthalene dicarboxyaldehyde and high-performance liquid chromatography with fluorescence detection.J Chromatogr. 1990 Dec 14;534:139-49. doi: 10.1016/s0378-4347(00)82156-8. J Chromatogr. 1990. PMID: 2094701
-
Column-switching high-performance liquid chromatographic method for the determination of SK&F 106203 in human plasma after fluorescence derivatization with 9-anthryldiazomethane.J Chromatogr. 1993 Feb 12;631(1-2):233-40. doi: 10.1016/0021-9673(93)80527-f. J Chromatogr. 1993. PMID: 8450016
-
Improved determination of the bisphosphonate alendronate in human plasma and urine by automated precolumn derivatization and high-performance liquid chromatography with fluorescence and electrochemical detection.J Chromatogr. 1992 Dec 2;583(2):183-93. doi: 10.1016/0378-4347(92)80551-z. J Chromatogr. 1992. PMID: 1478982
-
Sample preparation, high-performance liquid chromatographic separation and determination of substance P-related peptides.J Chromatogr B Biomed Appl. 1995 Mar 24;665(2):233-70. doi: 10.1016/0378-4347(94)00533-b. J Chromatogr B Biomed Appl. 1995. PMID: 7540916 Review.
-
Post-column reactors for sensitive and selective detection in high-performance liquid chromatography: categorization and applications.J Chromatogr. 1989 Aug 11;492:251-98. doi: 10.1016/s0378-4347(00)84471-0. J Chromatogr. 1989. PMID: 2670993 Review.