Composition and in vitro corrosion of orthodontic appliances
- PMID: 1350883
- DOI: 10.1016/0889-5406(92)70127-V
Composition and in vitro corrosion of orthodontic appliances
Abstract
The high incidence of nickel allergy and the increasing use of nickel-containing dental biomaterials has been of growing concern. The purpose of this investigation was to analyze different types of alloys used in orthodontics, and to study whether nickel and chromium will be released from these alloys when stored in physiologic saline. Face-bows, brackets, molar bands, and arch wires were analyzed. Most of the different parts in the face-bows, brackets, and molar bands were similar to conventional 18/8 stainless steel. Except the wires, most appliances included a variable amount of silver solder, the greatest in face-bows. After 14 days in 0.9% sodium chloride (NaCl), the largest amount of nickel and chromium were leached out from the face-bows and the least amount from the arch wires. Soldered stainless steel face-bows seemed to be very susceptible to corrosion. The release of nickel seemed to be related to both the composition and the method of manufacture of the appliances, but the release was not proportional to the nickel content.
Similar articles
-
Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro.Am J Orthod Dentofacial Orthop. 1993 Jan;103(1):8-14. doi: 10.1016/0889-5406(93)70098-9. Am J Orthod Dentofacial Orthop. 1993. PMID: 8422037
-
Biodegradation of nickel and chromium from space maintainers: an in vitro study.J Indian Soc Pedod Prev Dent. 2010 Jan-Mar;28(1):6-12. doi: 10.4103/0970-4388.60484. J Indian Soc Pedod Prev Dent. 2010. PMID: 20215665
-
Corrosion of silver soldered orthodontic wires.Acta Odontol Scand. 1982;40(2):75-9. doi: 10.3109/00016358209041118. Acta Odontol Scand. 1982. PMID: 6125077
-
Biocompatibility of nickel and cobalt dental alloys.Gen Dent. 2001 Sep-Oct;49(5):498-503; quiz 504-5. Gen Dent. 2001. PMID: 12017794 Review.
-
In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility.Angle Orthod. 2002 Jun;72(3):222-37. doi: 10.1043/0003-3219(2002)072<0222:IVAOOA>2.0.CO;2. Angle Orthod. 2002. PMID: 12071606 Review.
Cited by
-
In vitro physical, chemical, and biological evaluation of commercially available metal orthodontic brackets.Korean J Orthod. 2012 Dec;42(6):297-306. doi: 10.4041/kjod.2012.42.6.297. Epub 2012 Dec 28. Korean J Orthod. 2012. PMID: 23323244 Free PMC article.
-
Evaluation of nickel ion release from various orthodontic arch wires: An in vitro study.J Int Soc Prev Community Dent. 2014 Jan;4(1):12-6. doi: 10.4103/2231-0762.130921. J Int Soc Prev Community Dent. 2014. PMID: 24818088 Free PMC article.
-
An In Vitro Comparison of Nickel and Chromium Release from Crown and Loop Space Maintainers.Int J Clin Pediatr Dent. 2025 Feb;18(2):203-209. doi: 10.5005/jp-journals-10005-3082. Epub 2025 Mar 20. Int J Clin Pediatr Dent. 2025. PMID: 40417448 Free PMC article.
-
Effect of fluoride agents on surface characteristics of NiTi wires. An ex vivo investigation.J Oral Biol Craniofac Res. 2020 Oct-Dec;10(4):435-440. doi: 10.1016/j.jobcr.2020.07.006. Epub 2020 Aug 5. J Oral Biol Craniofac Res. 2020. PMID: 32817814 Free PMC article.
-
Review on Preformed Crowns in Pediatric Dentistry-The Composition and Application.Materials (Basel). 2022 Mar 11;15(6):2081. doi: 10.3390/ma15062081. Materials (Basel). 2022. PMID: 35329535 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources