An adapter for defined sample volumes makes it possible to count absolute particle numbers in flow cytometry
- PMID: 1356415
An adapter for defined sample volumes makes it possible to count absolute particle numbers in flow cytometry
Abstract
A device is described which makes it possible to count absolute particle (cell) numbers per volume by flow cytometry. It can easily by adapted to several types of flow cytometers, especially to the Coulter EPICS V and EPICS 750 series. A volume adapter has been installed in place of the normal sample handling system without any further modifications of the instrument or the data acquisition program. The adapter consists of a special pipette with two opto-electronic detectors for the beginning and end of the measuring period. These switch on/off a shutter for the illuminating laser beam so that acquisition of the data is controlled indirectly. Sample volumes of 50 microliters were measured at flow rates up to 10(3) particles/s. Calibration beads as well as blood cells were enumerated according to FALS (forward angle light scatter), to SSC (90 degrees light scatter), and to fluorescence parameters. The results were compared to the evaluation made on a Coulter counter or in a Neubauer chamber of a light microscope. Using a concentration of 1 x 10(5)-5 x 10(5) particles/ml, the absolute numbers of particles were determined with a high reproducibility and an estimated error rate of 2-5%.
Similar articles
-
A rapid mix flow cytometer with subsecond kinetic resolution.Cytometry. 1995 Nov 1;21(3):223-9. doi: 10.1002/cyto.990210302. Cytometry. 1995. PMID: 8582244
-
Quantitative determination of particle concentrations in experimental and marine environmental samples.Cytometry. 1994 Oct 1;17(2):179-84. doi: 10.1002/cyto.990170211. Cytometry. 1994. PMID: 7835169
-
High-speed particle detection in a micro-Coulter counter with two-dimensional adjustable aperture.Biosens Bioelectron. 2008 Oct 15;24(2):290-6. doi: 10.1016/j.bios.2008.04.005. Epub 2008 Apr 14. Biosens Bioelectron. 2008. PMID: 18511254
-
Flow cytometry instrumentation in research and clinical laboratories.Clin Lab Sci. 1993 May-Jun;6(3):167-73. Clin Lab Sci. 1993. PMID: 10146217 Review.
-
Flow cytometry: an introduction.Methods Mol Biol. 2011;699:1-29. doi: 10.1007/978-1-61737-950-5_1. Methods Mol Biol. 2011. PMID: 21116976 Review.
Cited by
-
Primary Determination of Particle Number Concentration with Light Obscuration and Dynamic Imaging Particle Counters.J Res Natl Inst Stand Technol. 2018 Jan 11;123:1-21. doi: 10.6028/jres.123.002. eCollection 2018. J Res Natl Inst Stand Technol. 2018. PMID: 34877136 Free PMC article.