Electrodes for blood pO2 and pCO2 determination
- PMID: 13587443
- DOI: 10.1152/jappl.1958.13.3.515
Electrodes for blood pO2 and pCO2 determination
Comment in
-
The significance of the blood gas analyzer.J Appl Physiol (1985). 2004 Nov;97(5):1597-8. doi: 10.1152/classicessays.00016.2004. J Appl Physiol (1985). 2004. PMID: 15475548 No abstract available.
-
First electrodes for blood PO2 and PCO2 determination.J Appl Physiol (1985). 2004 Nov;97(5):1599-600. doi: 10.1152/classicessays.00021.2004. J Appl Physiol (1985). 2004. PMID: 15475549 No abstract available.
-
Evaluation of a novel in-line point-of-care blood gas analyser.Anaesthesia. 2016 Sep;71(9):1044-52. doi: 10.1111/anae.13548. Anaesthesia. 2016. PMID: 27523052
Similar articles
-
A new electrode system for continuous measurement of PH, PCO2, PO2, and temperature on flowing blood.J Assoc Adv Med Instrum. 1970 Jul-Aug;4(4):136-44. J Assoc Adv Med Instrum. 1970. PMID: 5520703 No abstract available.
-
The determination of blood PCO2 and PO2 with electrodes in an open cuvette system.Pflugers Arch. 1970;314(2):161. Pflugers Arch. 1970. PMID: 5460724 No abstract available.
-
Determination of blood-gases utilizing specially designed electrodes for PCO2, PO2, PO2 and pH.Biomed Sci Instrum. 1967;3:181-8. Biomed Sci Instrum. 1967. PMID: 5582603 No abstract available.
-
[Transcutaneous electrodes for blood gas determination].Iyodenshi To Seitai Kogaku. 1983 Dec;21(7):524-30. Iyodenshi To Seitai Kogaku. 1983. PMID: 6431156 Review. Japanese. No abstract available.
-
[Intravascular electrodes for blood gas monitoring].Iyodenshi To Seitai Kogaku. 1983 Dec;21(7):517-23. Iyodenshi To Seitai Kogaku. 1983. PMID: 6431155 Review. Japanese. No abstract available.
Cited by
-
Acute effect of nitroglycerin on haemodynamics of angina pectoris.Br Heart J. 1968 May;30(3):407-11. doi: 10.1136/hrt.30.3.407. Br Heart J. 1968. PMID: 4967901 Free PMC article. No abstract available.
-
Respiratory function during sleep in patients with chronic obstructive lung disease.J Clin Invest. 1966 May;45(5):631-6. doi: 10.1172/JCI105378. J Clin Invest. 1966. PMID: 5935355 Free PMC article. No abstract available.
-
[Clinical usefulness of the platinum electrode according to Bartels and Reinhardt for the measurement of PO2 in the blood].Klin Wochenschr. 1961 Jun 1;39:594-6. doi: 10.1007/BF01485269. Klin Wochenschr. 1961. PMID: 13701381 German. No abstract available.
-
[The measurement of high oxygen pressure in small quantities of gases and fluids with the Pt-electrode].Pflugers Arch Gesamte Physiol Menschen Tiere. 1963;276:429-34. Pflugers Arch Gesamte Physiol Menschen Tiere. 1963. PMID: 13931530 German. No abstract available.
-
THE VASCULAR RESISTANCE OF THE FOETAL AND NEWLY VENTILATED LUNG OF THE LAMB.J Physiol. 1964 May;171(1):61-79. doi: 10.1113/jphysiol.1964.sp007361. J Physiol. 1964. PMID: 14170145 Free PMC article. No abstract available.
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources