Effects of tissue processing techniques in acoustical (1.2 GHz) and light microscopy
- PMID: 1373128
- DOI: 10.1007/BF00267311
Effects of tissue processing techniques in acoustical (1.2 GHz) and light microscopy
Abstract
In this study the influence of various tissue processing and staining techniques on the acoustical properties of liver tissue was investigated. A qualitative study was performed using ultrasound attenuation as the imaged parameter of a combined optical/acoustical microscope with a 1.2 GHz transducer. Images were made of three sets of adjacent liver sections (6 microns in thickness) which were prepared in ten different ways: fixed by alcohol or formalin; stained by hematoxylin-eosin (HE), toluidine blue (TB) or non-stained; sectioned by a cryostat or by a paraffin microtome. It was concluded that the images obtained from cryostat sections were of much higher quality than those from paraffin sections. Images obtained from sections that were sectioned while embedded in paraffin displayed no detail at all. No consistent effect was noticed with respect to staining by HE or TB. Alcohol fixed sections gave more detailed images than formalin fixed sections. Formalin fixation in combination with cryostat sectioning yielded many cytoplasmic vacuoles.
Similar articles
-
Preservation and Processing of Intestinal Tissue for the Assessment of Histopathology.Methods Mol Biol. 2021;2223:267-280. doi: 10.1007/978-1-0716-1001-5_18. Methods Mol Biol. 2021. PMID: 33226600
-
Fluorescence of hematoxylin and eosin-stained histological sections of the human spleen.Acta Histochem. 2002;104(4):353-6. doi: 10.1078/0065-1281-00684. Acta Histochem. 2002. PMID: 12553701
-
A Pilot Validation Study Comparing Fluorescence-Imitating Brightfield Imaging, A Slide-Free Imaging Method, With Standard Formalin-Fixed, Paraffin-Embedded Hematoxylin-Eosin-Stained Tissue Section Histology for Primary Surgical Pathology Diagnosis.Arch Pathol Lab Med. 2024 Mar 1;148(3):345-352. doi: 10.5858/arpa.2022-0432-OA. Arch Pathol Lab Med. 2024. PMID: 37226827 Free PMC article.
-
The hematoxylin and eosin stain in anatomic pathology-An often-neglected focus of quality assurance in the laboratory.Semin Diagn Pathol. 2019 Sep;36(5):303-311. doi: 10.1053/j.semdp.2019.06.003. Epub 2019 Jun 4. Semin Diagn Pathol. 2019. PMID: 31230963 Review.
-
Making Formalin-Fixed, Paraffin Embedded Blocks.Methods Mol Biol. 2019;1897:253-268. doi: 10.1007/978-1-4939-8935-5_22. Methods Mol Biol. 2019. PMID: 30539450 Review.
Cited by
-
Effect of temperature and fixation on the optical properties of atherosclerotic tissue: a validation study of an ex-vivo whole heart cadaveric model.Biomed Opt Express. 2014 Mar 3;5(4):1038-49. doi: 10.1364/BOE.5.001038. eCollection 2014 Apr 1. Biomed Opt Express. 2014. PMID: 24761287 Free PMC article.
-
Layer-dependent variation in the anisotropy of apparent integrated backscatter from human coronary arteries.Ultrasound Med Biol. 2011 Apr;37(4):632-41. doi: 10.1016/j.ultrasmedbio.2011.01.007. Epub 2011 Mar 3. Ultrasound Med Biol. 2011. PMID: 21376456 Free PMC article.