Modelling magnetic coil excitation of human cerebral cortex with a peripheral nerve immersed in a brain-shaped volume conductor: the significance of fiber bending in excitation
- PMID: 1385089
- DOI: 10.1016/0168-5597(92)90105-k
Modelling magnetic coil excitation of human cerebral cortex with a peripheral nerve immersed in a brain-shaped volume conductor: the significance of fiber bending in excitation
Abstract
To help elucidate some basic principles of magnetic coil (MC) excitation of cerebral cortex, a model system was devised in which mammalian phrenic nerve, or amphibian sciatic nerve with its branches was suspended in appropriate Ringer's solution in a human brain-shaped volume conductor, an inverted plastic skull. The nerve was recorded monophasically out of the volume conductor. The site of nerve excitation by the MC was identified by finding where along the nerve a bipolar electrical stimulus yielded a similar action potential latency. MC excitation of hand-related corticospinal (CT) neurons was modelled by giving the distal end of nerve attached to the lateral skull an initial radial (perpendicular) trajectory, with subsequent bends towards the base and posterior part of the skull; this nerve was optimally excited by a laterally placed figure 8 or round MC when the induced electric field led to outward membrane current at the initial bend. By contrast, nerve given a trajectory modelling CT neurons related to the foot was optimally excited when the coil windings were across the midline, but again when membrane current flowed outward at the first bend. Corticocortical fibers were modelled by placing the nerve in the anteroposterior axis lateral to the midline; with the round MC vertex-tangentially orientated, optimal excitation occurred at the bend nearest the interaural line, i.e., near the peak electric field. The findings emphasize the importance of orientation and direction of current in the MC and fiber bends in determining nerve excitation. The findings in the peripheral nerve-skull model help explain (1) why lateral and vertex-tangentially orientated MCs preferentially excite arm-related CT neurons directly and indirectly (through corticocortical fibers), respectively, and (2) why the MC orientations for optimally exciting directly arm and leg-related CT neurons differ.
Similar articles
-
Magnetic coil stimulation of straight and bent amphibian and mammalian peripheral nerve in vitro: locus of excitation.J Physiol. 1993 Jan;460:201-19. doi: 10.1113/jphysiol.1993.sp019467. J Physiol. 1993. PMID: 8487192 Free PMC article.
-
Matching focal and non-focal magnetic coil stimulation to properties of human nervous system: mapping motor unit fields in motor cortex contrasted with altering sequential digit movements by premotor-SMA stimulation.Electroencephalogr Clin Neurophysiol Suppl. 1991;43:3-28. Electroencephalogr Clin Neurophysiol Suppl. 1991. PMID: 1773769 Review.
-
A comparison of corticospinal activation by magnetic coil and electrical stimulation of monkey motor cortex.Electroencephalogr Clin Neurophysiol. 1990 Sep-Oct;77(5):390-401. doi: 10.1016/0168-5597(90)90061-h. Electroencephalogr Clin Neurophysiol. 1990. PMID: 1697531
-
Spatial distribution of the electric field induced in volume by round and figure '8' magnetic coils: relevance to activation of sensory nerve fibers.Electroencephalogr Clin Neurophysiol. 1990 Aug;76(2):131-41. doi: 10.1016/0013-4694(90)90211-2. Electroencephalogr Clin Neurophysiol. 1990. PMID: 1697241
-
Stimulation of the human nervous system using the magnetic coil.J Clin Neurophysiol. 1991 Jan;8(1):38-55. doi: 10.1097/00004691-199101000-00006. J Clin Neurophysiol. 1991. PMID: 2019650 Review.
Cited by
-
Assessing cortical network properties using TMS-EEG.Hum Brain Mapp. 2013 Jul;34(7):1652-69. doi: 10.1002/hbm.22016. Epub 2012 Feb 29. Hum Brain Mapp. 2013. PMID: 22378543 Free PMC article.
-
Nonphysiological factors in navigated TMS studies; confounding covariates and valid intracortical estimates.Hum Brain Mapp. 2015 Jan;36(1):40-9. doi: 10.1002/hbm.22611. Epub 2014 Aug 29. Hum Brain Mapp. 2015. PMID: 25168635 Free PMC article.
-
Short-latency subliminal effects of transcranial magnetic stimulation on forearm motoneurones.Exp Brain Res. 1993;96(3):513-8. doi: 10.1007/BF00234119. Exp Brain Res. 1993. PMID: 8299752
-
Biomarkers Obtained by Transcranial Magnetic Stimulation in Neurodevelopmental Disorders.J Clin Neurophysiol. 2022 Feb 1;39(2):135-148. doi: 10.1097/WNP.0000000000000784. J Clin Neurophysiol. 2022. PMID: 34366399 Free PMC article.
-
Investigating the cortical regions involved in MEP modulation in tDCS.Front Cell Neurosci. 2015 Oct 13;9:405. doi: 10.3389/fncel.2015.00405. eCollection 2015. Front Cell Neurosci. 2015. PMID: 26528134 Free PMC article.